228-1363 COND/CONFORM 073113
B
Conditions of Conformance
Rack Adapter products (EN60950)
When this product is used in applications governed by the requirements of the EEC, the following restric-
tions and conditions apply:
1. For European applications, requiring compliance to the Low Voltage Directive, 73/23/EEC, this Rack
Adapter is considered a component, designed for “building in”. Because it is incomplete in construc-
tion, the end product enclosure must provide for compliance to any remaining electrical safety require-
ments and act as a fire enclosure. (EN60950, CL.2.1, 2.7, 3.3, 4.3 and 4.4.5).
2. This Rack Adapter is designed for stationary installation, with mains power applied via a detachable
power supply cord or via direct wiring to a source power terminal block.
3. This Rack Adapter, when properly installed, is considered a Class 1 (earthed) product, and as such
depends upon proper connection to protective earth for safety from electric shock. (EN60950 Cl. 2.5)
4. This product is intended for use as part of equipment meant for an Information Technology Equipment
environment. It is designed to operate from single phase, three wire TN power systems. This equip-
ment must be installed within a suitably wired equipment rack, utilizing a three wire (grounded) mains
connection. See wiring section of this manual for complete electrical wiring instructions.
5. When fitted with the appropriate power supplies, this product may have secondary output circuits that
are considered hazardous, and which exceed 240 VA at a potential of 2V or more.
6. The output wiring terminals of this power supply have not been evaluated for field wiring and, there-
fore, must be properly configured by the end product manufacturer prior to use.
7. For complete circuit protection of the end product, as well as the building wiring, it is required that a pri-
mary circuit protection device be fitted to the branch circuit wiring. (EN60950 Cl. 2.5).
8. When installed with other components and/or power supplies, hazardous voltages may be present
within the equipment during normal operation. All operator adjustments are made via externally acces-
sible switches, controls and signal lines as specified within the individual power supply operating
instructions. There are no user or operator serviceable parts within this product enclosure. Refer all
servicing to qualified and trained Kepco service technicians.
Summary of Contents for RA 60
Page 8: ...iv RA60 SERIES073113 FIGURE 1 1 SERIES RA 60 RACK ADAPTER...
Page 22: ......