background image

2

228-1552 REV 2

 061510

KEPCO, INC. 

   

 131-38 SANFORD AVENUE 

 

  FLUSHING, NY. 11355 U.S.A.

 

  TEL (718) 461-7000

   

 FAX (718) 767-1102

  

http://www.kepcopower.com   

 

 email: [email protected]

LEAKAGE CURRENT: 

Cold start:

100V a-c and 60 Hz (single pole switching) (operating

in conformance with Den-An):

    0.75mA max, 0.2mA typ

240V a-c and 60 Hz (single pole switching in confor-

mance to UL 1950/IEC 950):

    0.75mA max, 0.35mA typ

POWER FACTOR: 

100V a-c: 0.99 typ.

240V a-c: 0.95 typ.

OUTPUT CHARACTERISTICS:

SOURCE EFFECT:  

(85 to 265 Va-c) 

0.4% max.

LOAD EFFECT: 

measured at sensing terminals

 (0% - 100% load change)

0.8% max.

TEMPERATURE EFFECT: 

(-10 to 60°C)

1.0% max.

COMBINED EFFECT: 

2.0% max. (4% typical for overshoot at start-up)

TIME EFFECT OR DRIFT: 

(1/2 to 8 hr. at 25°C) 

0.4% max.

TRANSIENT RECOVERY: 

 A step load change from

50% to 100% of rated load in 50 microseconds or more

produces no more than 4% output voltage excursion.

Temperature range from -10 to 60°C. Recovery time is

1mS maximum.

 HOLD UP TIME: 

Condition: 100% output load. Upon

input interruption the output is maintained for: 

100 Va-c:    40mS typ.
240 Va-c:    40mS typ.

START UP TIME: 

100 Va-c:    500mS max., 400mS typ.
240 Va-c:    500mS max., 300mS typ.

OVERVOLTAGE PROTECTION: 

Fixed, factory set.

See Table 1. Latching will occur.

OVERCURRENT: 

Square type, output voltage returns

to rated level upon removal of cause of malfunction (long

term overcurrent could damage unit).

ENVIRONMENTAL CHARACTERISTICS

OPERATING TEMPERATURE:  

-10 to 60°C (start up

-20 to -10°C). See the derating, Figure 1. 

STORAGE TEMPERATURE:  

-30°C to + 75°C.

COOLING:  

Natural convection. Do not allow the power

supply to become dust covered because that will

decrease the cooling efficiency of the unit and cause insu-

lation to deteriorate.

ORIENTATION:  

Vertical or horizontal (see Figure 2).

HUMIDITY:  

10% to 90% relative humidity, operating

and storage, noncondensing, wet bulb temperature < or =

35°C.

VIBRATION:  

Three axes, one hour each, sweep time

10 min., nonoperating.

5-10 Hz., 10 mm amplitude
10-200 Hz., 2G (19.6m/s

2

) acceleration

SHOCK:  

Three axes, 60G (588m/s

2

), 11 mS ±5mSec

pulse duration, three shocks each axis, nonoperating, 1/2

sine pulse.

GENERAL CHARACTERISTICS

WITHSTANDING VOLTAGE:  

(at 5 to 35°C ambient,

45 to 85% relative humidity, cutout current 10 mA):

Between input and output terminals: 

3.0 KV a-c for 1 minute. 

Between input terminals and ground:

2000V a-c for 1 minute. 

Between output terminals and ground:

500V a-c for 1 minute.

INSULATION RESISTANCE:  

Between input and out-

put, input and ground, output and ground: 100 megohms

minimum (500V d-c, 5 to 35°C ambient, 45 to 85% relative

humidity)

SAFETY:  

All units designed to meet UL 60950-1.c, and

TÜV Rheinland EN60950-1 (ambient temp. 50°C max.).

JBW 100W units are CE marked per the Low Voltage

Directive (LVD), EN60950. 

EMC - EMISSIONS:  

• Conducted Noise: 0.15MHz to 30MHz: 

FCC Class B, VCCI-B, EN55011-B, EN55022-B.

• Input Harmonics (on AC Mains) 0 to 2KHZ: 

EN 61000-3-2.

EMC - IMMUNITY:  

Designed to meet EN 61000-6-2.

• ESD: 

  EN 61000-4-2 Level 4, Normal operation.

• Radiated Field Noise: 

  EN 61000-4-3 Level 3, Normal operation.

• Electrical Fast Transient/Burst (EFT): 

  EN 61000-4-4 Level 3, Normal operation.

• Surge: 

  EN 61000-4-5 Level 4, no damage.

• Conducted Noise: 

  EN 61000-4-6 Level 3, Normal operation.

• Power Frequency Magnetic Field: 

  EN 61000-4-8 Level 4, Normal operation.

• Interruptions and voltage dips, short variations: 

  EN 61000-4-11, Normal operation.

WARRANTY:  

One year.