IV — SPECIFICATIONS (C, T, X, Y)

The following specifications apply to all HSF-PFCC,
PFCT, PFCX, and PFCY (suffix C, T, X, Y) 150 Watt
Series models. Table 2 lists the specifications that differ
for each model. Common specifications that apply to all

suffix C, T, X, Y models are listed in the paragraphs follow-
ing Table 2.

NOTE

: Specifications apply to all models except where

otherwise indicated.

INPUT: 

Voltage: 

Nominal:120V a-c/240V a-c; 
Range: 

90-264V a-c; 
110-370V d-c. (polarity insensitive) 

Frequency: Nominal: 50-60 Hz; Range: 47-440Hz

(From 66 to 440 Hz leakage current may exceed
UL/VDE safety spec. limit.)

Initial Turn-on Surge: (Cold start, first surge only, not

including the current flow into the EMI filter): 

14A typ. @100V a-c rms
28A typ. @200V a-c rms

Switching Frequency: 

145 KHz typical, PFC: 80KHz 

Current (nominal output at rated load):

1.9A rms max. @100-120 Va-c, 100% load
1.0A rms max. @200-240 Va-c, 100% load

 

3.3V Model: 

1.6A rms max @100 - 120V a-c: 
0.85A rms max. @200 - 240V a-c: 

24V Model:
     2.7A rms typ. @100 Va-c
     1.1A rms typ. @240 Va-c.

Power Factor: 0.99@100V a-c, 0.96@240V a-c

STABILIZATION: 

Source Effect (full load): 0.1% typ.;0.2% max 

Range 85-132V a-c or 170-265V a-c, 

Load Effect (10% to100% load change): 

0.5% typ.; 1.5% max 

TABLE 2.   OUTPUT RATINGS AND SPECIFICATIONS, (SUFFIX C, T, X, Y ONLY)

MODEL

HSF 3.3-30

PFCC

PFCT
PFCX
PFCY

HSF 5-30

PFCC

PFCT
PFCX
PFCY

HSF 12-12

PFCC

PFCT
PFCX
PFCY

HSF 15-10

PFCC

PFCT
PFCX
PFCY

HSF 24-6.3

PFCC

PFCT
PFCX
PFCY

HSF 28-5.3

PFCC

PFCT
PFCX
PFCY

HSF48-3.1

PFCC

PFCT
PFCX
PFCY

OUTPUT VOLTS, d-c (NOMINAL)

3.3V

5V

12V

15V

24V

28V

48V

ADJUSTMENT RANGE

2.8 - 3.4V

4.3 - 5.3V

9.8 - 13.0V

12.8 - 16.3V

19.2 - 26.0V

23.0 - 30.2V

40.0 - 52.2

OVERVOLTAGE SETTING 

(1) (2)

3.4 - 4.6V

5.2 - 6.5V

13.2 - 15.2V

16.8 - 18.8V

26.5 - 30.3V

31.5 - 34.8V

54.5 - 59.8V

OUTPUT CURRENT, NOMINAL

30A

30A

12.5A

10A

6.3A 

(10A Peak

(7)

5.3A

3.1A

CURRENT LIMIT SETTING 

(2) (3)

38.5 - 45.5A

33.0-39.0A

13.7-16.3A

11.0-13.0A

10.5-13.5A

5.94-7.02A

3.52-4.16A

OUTPUT POWER, MAX 

(4)

100W

150W

150W

150W

151.2W

151.2W

153.6W

EFFICIENCY (typ.)

100 Va-c

80%

83%

84%

84%

86%

86%

86%

240 Va-c

83%

86%

87%

87%

88%

88%

89%

RIPPLE AND NOISE 

(5)

(mV p-p)

0-40°C, 10-100% LOAD

switching (max.)

80

80

100

100

150

150

200

spike noise (max.)

(d-c—50MHz)

120

120

150

150

200

200

300

SENSE RESISTOR VALUE (milliohms) 

(6)

2.5

2.5

10

10

20

20

30

(1) Overvoltage (and overtemperature on 24V model) shuts down the output.

Recover by recycling a-c input (approximately 30 second delay required
before resetting). For overtemperature, allow unit to cool before resetting.

(2) 25°C, Nominal. Input.
(3) Hiccup mode operation. After the cause of overcurrent is removed, output

voltage recovers automatically.

(4) See power rating curve, Figure 4. Exceeding maximum power rating may

result in oscillation or a drop in output current or voltage.

(5) Ripple and noise will be approximately 1.5 times higher in the operating temper-

ature range -10 to 0°C. 

(6) Sense resistor on C and Y Models are used for current monitoring. See “Current

Monitor.” on page 2 for details.

(7) Peak current and thermal protection applicable to 24V model only. See Figure 1

for peak power requirements. 

Summary of Contents for HSF 12-13PFC

Page 1: ...page 4 standard models and Section IV on page 6 suffix C T X and Y OPTIONS Options are identified by suffix T PFCT offers improved efficiency and less weight C PFCC offers current monitoring via an integral current sensing resistor includes option T X PFCX offers remote on off includes option T and Y PFCY includes options C X and T II FEATURES FRONT PANEL ACCESS The front panel provides a power ON...

Page 2: ...line ac input line failure etc results in an alarm All models include an isolated internal relay offering nor mally closed and normally open contacts referenced to an isolated common These contacts are rated for 1A at 30V d c and 0 5A at 125V a c These contacts may be used to configure close on failure or open on failure alarm cir cuits see Figure 3 for typical alarm circuits Refer to the applicab...

Page 3: ... each other and each unit must be operating at between 10 to 100 of rated output current If current to the load goes below 10 for each unit in cur rent share mode all MASTER ON lights may go on see load effect specifications this indicates that forced current share is no longer working units are simply in automatic current share mode If forced current sharing at less than 10 nominal current per su...

Page 4: ... 265V a c Load Effect 10 100 load change 0 5 typ 1 5 max except 3 3V model 1 typ 2 max Temperature Effect Range 10o to 71o C 0 5 typ 1 0 max Combined Effect includes source load and temperature effects 0 9 typ 1 8 max except 3 3V model 1 typ 2 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max TABLE 1 OUTPUT RATINGS AND SPECIFICATIONS HSF PFC 150W SERIES STANDARD NO SUFFIX MODEL HSF 3 3 30PFC HS...

Page 5: ...ient 10 to 85 relative humidity 100 Megohms min LEAKAGE CURRENT Per IEC 950 and UL 1950 0 23 mA typ 0 35 mA max 120V a c 60Hz 0 45 mA typ 0 7 mA max 240V a c 60Hz SAFETY All units designed to meet EN 60950 U S UL 60950 3rd Ed Canada CAN CSA 22 2 No 60950 00 3rd Ed ambient temp 50 C 150W units are CE marked per the Low Voltage Directive LVD EN60950 The standards do not apply with DC input operation...

Page 6: ...2 PFCC PFCT PFCX PFCY HSF 15 10 PFCC PFCT PFCX PFCY HSF 24 6 3 PFCC PFCT PFCX PFCY HSF 28 5 3 PFCC PFCT PFCX PFCY HSF48 3 1 PFCC PFCT PFCX PFCY OUTPUT VOLTS d c NOMINAL 3 3V 5V 12V 15V 24V 28V 48V ADJUSTMENT RANGE 2 8 3 4V 4 3 5 3V 9 8 13 0V 12 8 16 3V 19 2 26 0V 23 0 30 2V 40 0 52 2 OVERVOLTAGE SETTING 1 2 3 4 4 6V 5 2 6 5V 13 2 15 2V 16 8 18 8V 26 5 30 3V 31 5 34 8V 54 5 59 8V OUTPUT CURRENT NOM...

Page 7: ...00V a c for one minute Between input and case ground 2KV a c for one minute INSULATION RESISTANCE Between input and ground output and ground input and output 500V d c 15 to 35 C ambient 10 to 85 relative humidity 100 Megohms min LEAKAGE CURRENT Per IEC 950 and UL 1950 0 29 mA typ 0 45 mA max 120V a c 60Hz 0 40 mA typ 0 65 mA max 240V a c 60Hz SAFETY All units designed to meet EN 60950 2001 U S UL ...

Page 8: ...o fault When output voltage is available the green VDC ON LED is on While monitoring output voltage at the front panel test points the Output Voltage Adjust trimmer allows adjustment of the output voltage FIGURE 5 COMPONENT LOCATIONS Master slave parallel configurations of one or more power supplies are covered in the applicable RA 19 X B Rack Adapter manual The MASTER ON LED amber goes on under a...

Page 9: ...ANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com 081721 228 1550 REV 17 9 FIGURE 6 HSF PFC 150W INCLUDING SUFFIX C T X AND Y POWER SUPPLY OUTLINE DRAWING ...

Reviews: