FIGURE 1.  24 V MODEL PEAK CURRENT REQUIREMENTS

REMOTE ON-OFF.  

Remote on-off (X and Y models

only) is via ±RC assigned to pins of the RA 19-(X)B I/O
connector: off = no voltage, short circuit, or 0 to 0.8V, on =
4.5 to 12.5V (or 12.5 to 24.5V via 1.5K Ohms). To reverse
on-off polarity contact Kepco. There is no isolation
between ±RC, d-c output and alarm circuit. Refer to the
applicable RA 19-(X)B Manual for details.

CURRENT MONITOR. 

Current monitor (C and Y

models only) is via ±IMON assigned to pins of the RA 19-
(X)B I/O connector. Monitored Output Current (Amps) =
Voltage drop across R

EQ

 (mVolts) / R

EQ

 (mOhms) where

R

EQ

 is the sum of R

S

 (see Table 2) + trace resistance to

point where current monitor is connected, approximately
4mOhms. The voltage drop across R

EQ

 is measured

across ± IMON pins (requires millivoltmeter, range 0 to
250mV). Accuracy is ±10%; contact Kepco if greater
accuracy is required. There is no isolation between
±IMON, alarm circuit and d-c output. Refer to the applica-
ble RA 19-(X)B Manual for details.

ALARM CIRCUIT.  

Any condition which causes the

unit to be out of specified voltage/current ranges (includ-
ing overvoltage, overcurrent, overtemperature, open
sense line, ac input line failure, etc.) results in an alarm.
All models include an isolated internal relay offering nor-
mally closed and normally open contacts referenced to an
isolated common. These contacts are rated for 1A at 30V
d-c and 0.5A at 125V a-c. These contacts may be used to
configure “close on failure” or “open on failure” alarm cir-
cuits (see Figure 3 for typical alarm circuits). Refer to the
applicable RA 19-(X)B Manual for details about the follow-
ing: 1) normally open (close on failure) contacts are not
available if ±RC is used on X and Y suffix models, 2)
alarm signals are not isolated on C, X and Y models and
3) alarm configurations for multiple power supplies. 

KEYING. 

Keying of the power supply is established at

the factory. The output voltage determines which keyway
is open. When the corresponding rack adapter key (pin) is
installed by the user, only a power supply of the correct
voltage can be inserted in the rack adapter slot.

FIGURE 2.  HSF-PFC 150 WATT POWER SUPPLIES (6) INSTALLED IN RA 19-6B RACK ADAPTER

3043527

I

1

I

2

T

t

D=(t/T)

24V Models (with or without options) can supply Peak
current listed in Table 1 or 2 if the four conditions listed
below are met. This model includes thermal protection,
voltage shutdown type. Restart by removing a-c input;
after sufficient cooling, reapply a-c input (wait at least 30
seconds).

1. Time: t 



10 Seconds

2. 

I

1

 



Peak Current (Amperes)

3. Effective Current:

 

 

 Rated current (Amperes)

4. Effective Power P 

 Maximum Power (Watts)

    (output RMS current x output voltage)

DI1

2

I

D

I2

2

+

Summary of Contents for HSF 12-13PFC

Page 1: ...page 4 standard models and Section IV on page 6 suffix C T X and Y OPTIONS Options are identified by suffix T PFCT offers improved efficiency and less weight C PFCC offers current monitoring via an integral current sensing resistor includes option T X PFCX offers remote on off includes option T and Y PFCY includes options C X and T II FEATURES FRONT PANEL ACCESS The front panel provides a power ON...

Page 2: ...line ac input line failure etc results in an alarm All models include an isolated internal relay offering nor mally closed and normally open contacts referenced to an isolated common These contacts are rated for 1A at 30V d c and 0 5A at 125V a c These contacts may be used to configure close on failure or open on failure alarm cir cuits see Figure 3 for typical alarm circuits Refer to the applicab...

Page 3: ... each other and each unit must be operating at between 10 to 100 of rated output current If current to the load goes below 10 for each unit in cur rent share mode all MASTER ON lights may go on see load effect specifications this indicates that forced current share is no longer working units are simply in automatic current share mode If forced current sharing at less than 10 nominal current per su...

Page 4: ... 265V a c Load Effect 10 100 load change 0 5 typ 1 5 max except 3 3V model 1 typ 2 max Temperature Effect Range 10o to 71o C 0 5 typ 1 0 max Combined Effect includes source load and temperature effects 0 9 typ 1 8 max except 3 3V model 1 typ 2 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max TABLE 1 OUTPUT RATINGS AND SPECIFICATIONS HSF PFC 150W SERIES STANDARD NO SUFFIX MODEL HSF 3 3 30PFC HS...

Page 5: ...ient 10 to 85 relative humidity 100 Megohms min LEAKAGE CURRENT Per IEC 950 and UL 1950 0 23 mA typ 0 35 mA max 120V a c 60Hz 0 45 mA typ 0 7 mA max 240V a c 60Hz SAFETY All units designed to meet EN 60950 U S UL 60950 3rd Ed Canada CAN CSA 22 2 No 60950 00 3rd Ed ambient temp 50 C 150W units are CE marked per the Low Voltage Directive LVD EN60950 The standards do not apply with DC input operation...

Page 6: ...2 PFCC PFCT PFCX PFCY HSF 15 10 PFCC PFCT PFCX PFCY HSF 24 6 3 PFCC PFCT PFCX PFCY HSF 28 5 3 PFCC PFCT PFCX PFCY HSF48 3 1 PFCC PFCT PFCX PFCY OUTPUT VOLTS d c NOMINAL 3 3V 5V 12V 15V 24V 28V 48V ADJUSTMENT RANGE 2 8 3 4V 4 3 5 3V 9 8 13 0V 12 8 16 3V 19 2 26 0V 23 0 30 2V 40 0 52 2 OVERVOLTAGE SETTING 1 2 3 4 4 6V 5 2 6 5V 13 2 15 2V 16 8 18 8V 26 5 30 3V 31 5 34 8V 54 5 59 8V OUTPUT CURRENT NOM...

Page 7: ...00V a c for one minute Between input and case ground 2KV a c for one minute INSULATION RESISTANCE Between input and ground output and ground input and output 500V d c 15 to 35 C ambient 10 to 85 relative humidity 100 Megohms min LEAKAGE CURRENT Per IEC 950 and UL 1950 0 29 mA typ 0 45 mA max 120V a c 60Hz 0 40 mA typ 0 65 mA max 240V a c 60Hz SAFETY All units designed to meet EN 60950 2001 U S UL ...

Page 8: ...o fault When output voltage is available the green VDC ON LED is on While monitoring output voltage at the front panel test points the Output Voltage Adjust trimmer allows adjustment of the output voltage FIGURE 5 COMPONENT LOCATIONS Master slave parallel configurations of one or more power supplies are covered in the applicable RA 19 X B Rack Adapter manual The MASTER ON LED amber goes on under a...

Page 9: ...ANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 www kepcopower com email hq kepcopower com 081721 228 1550 REV 17 9 FIGURE 6 HSF PFC 150W INCLUDING SUFFIX C T X AND Y POWER SUPPLY OUTLINE DRAWING ...

Reviews: