Q U I C K   S T A R T   G U I D E

KEPCO

An ISO 9001 Company.

BOP

400W

100W, 200W,

BIPOLAR OPERATIONAL

POWER SUPPLY

I — INTRODUCTION

1.1.  SCOPE OF MANUAL. 

This Quick Start Guide

covers simple installation and local operation of the Kepco
100W, 200W and 400W Series of BOP Bipolar Operational
Power Supplies. Full specifications, features and instruc-
tions are found in the BOP Operator Manual that can be
downloaded free from the Kepco web site at:

   www.kepcopower.com/support/opmanls.htm#bop-op

1.2.  DESCRIPTION. 

Kepco’s BOP are linear stabilizers

with two bipolar control channels (voltage or current mode),
selectable and individually controllable either by front panel
controls, or by remote signals. These two principal control
channels are each protected by bipolar limit circuits. The
positive and negative current or voltage limit points can be
manually set or remotely programmed simultaneously or
Individually. Automatic crossover between each principal
control channel and the limit channels is provided. Only
one principle channel (voltage or current) can control the
output at any one time.

The BOP can operate in all four voltage-current quadrants;
it can act as either a source (output voltage is the same
direction as output current) or a sink (output voltage is
opposite that of output current). An example is shown in
Figure 1 where the BOP is programmed to deliver a sine
wave output and the load produces a phase shift between
the output voltage and current. See applicable BOP Opera-
tor Manual (PAR. 1.1) for limits on long-term operation in
sink mode.

Units are shipped for 115V a-c operation (105V to 125V
a-c), 57 to 63Hz. For operation at 104V a-c, 208V a-c or
230V a-c refer to the full Operator Manual (PAR 1.1).

1.3.  OPTIONS. 

Standard models (M suffix) include ana-

log voltage and current meters. Models with a D suffix
include digital meters. Models optimized to operate in cur-
rent mode with large inductive loads are identified by suffix
L. Models optimized to operate in voltage mode with large

capacitive loads are identified by suffix C. Models with digi-
tal control via GPIB or RS 232 are identified by suffix 4886.
Models with digital control via ethernet/LAN are identified
by suffix 802E. An isolated on-off port to providing remote
on-off control of the output and associated flag signal is
included on BOP 5-20DL; contact Kepco to include this
option in other models.

FIGURE 1.  SINK OPERATION PRODUCED BY LOAD 

PHASE SHIFT

1.4.  EQUIPMENT SUPPLIED. 

• PC 15 connector (PC 12 wired for front panel con-

trol) MUST be installed at rear panel to enable 
local operation.

• 115V a-c Line Cord

1.5.  ACCESSORIES (NOT SUPPLIED) 

• Slides (Full rack only)

• Rack adapter RA 24 or RA 37 (mount 3/4 rack unit 

in 19-inch rack)

Summary of Contents for BOP 100W

Page 1: ...s it can act as either a source output voltage is the same direction as output current or a sink output voltage is opposite that of output current An example is shown in Figure 1 where the BOP is prog...

Page 2: ...service 3 2 PRELIMINARY CHECKOUT A simple oper ating check after unpacking and before permanent instal lation is advisable to ascertain whether the BOP has suffered damage in shipment 1 Install PC15...

Page 3: ...reduces noise ripple that may be present at the output REMOTE SENSE CONNECTIONS Remote sensing con necting the corresponding SENSE terminals to the OUT PUT and COMMON terminations at the load instead...

Page 4: ...NUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 2 BOP FULL RACK FRONT PANEL CONTROLS INDICATORS AND TERMINATIONS FIGURE 3 BOP 3 4 R...

Page 5: ...L OPENINGS AND THE TOP OF THE CASE MUST BE KEPT CLEAR FROM ALL OBSTRUCTIONS TO ENSURE AIR CIRCU LATION Periodic cleaning of the interior of the power sup ply is recommended If the BOP is rack mounted...

Page 6: ...ter as desired recommended to be 10 greater than the maximum negative volt age required for the load monitoring the VOLT AGE meter for the correct limiting value b Turn CURRENT CONTROL fully clockwise...

Page 7: ...d monitoring the CURRENT meter for the correct limiting value c Set the VOLTAGE CONTROL switch to OFF Set a c POWER switch circuit breaker to OFF then remove the short circuit from the output but leav...

Page 8: ...8 228 1678 REV 1 081415 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com...

Reviews: