ICS 3-304.81 Safety Recommendations: 

Consideration should be given to the use of an emergency stop function, which is independent of the 
programmable controller. 
Where the operator is exposed to the machinery, such as in loading or unloading a machine tool, or where the 
machine cycles automatically, consideration should be given to the use of an electromechanical override or other 
redundant means, independent of the programmable controller, for starting and interrupting the cycle. 
If provision is required for changing programs while the equipment is in operation, consideration should be given to
the use of locks or other means of assuring that only authorized personnel can make such changes. These 
recommendations are intended as safeguards against the failure of critical components and the effects of such 
failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in 
operation. * 

The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical 
Manufacturers Association from NEMA ICS 3-304 

2.3 Communications Connections 

The ports as you look at the back of the case, are the ports for connecting to a PLC or some external 
device (Controller Connectors). 

2.3.1 Connector COM1 [RS232], COM2 [RS232]

Cable 
Requirements 
Caution

Different cables are required for various devices. 
 
Restrict cable length to less than 500’ (150m) for RS485/422 devices and 
50’ (15m) for RS232 devices to avoid communications problems. 

The COM light on the front of the MMI8000 turns on with each Ethernet communication. 

Shielded cable must be used for long lengths or cables run in an electrically noisy environment. 
Do not run cables next to AC power lines or near sources of electrical noise. 

Be sure that the cable ends have been inserted all of the way into mating connectors and are 
secure

Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232] and COM2 
[RS-232] Port. 

Pin #

Symbol

COM1 [RS232]

COM2 [RS232]

1

Not used

2

RxD

Received Data

3

TxD

Transmitted Data

4

TxD

Transmitted Data

5

GND

Signal Ground

Signal Ground

6

RxD

Received Data

7

RTS

Ready to send output

8

CTS

Clear to send input

9

Not used

Pin 
Designations 

COM1 [RS-232] 
COM2 [RS-232

]

Summary of Contents for MMI6056

Page 1: ...has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Prope...

Page 2: ...be installed where fast temperature variations and or high humidity are present This causes condensation of water in the device Do not install these terminals in environments where inflammable gases a...

Page 3: ...cted to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an MMI8000 comply with EMC directives an...

Page 4: ...built into the program with an out of limit safe shut down procedure to ensure safety of personnel...

Page 5: ...ermission of the National Electrical Manufacturers Association from NEMA ICS 3 304 2 3 Communications Connections The ports as you look at the back of the case are the ports for connecting to a PLC or...

Page 6: ...Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground Signal Ground Signal Ground Signal Ground 6 Data Data 7 TxD Transmit 8 RxD Receive 9 Data Data 2 3 3 USB Host port Supports various devices with USB interface s...

Page 7: ...ilder8000 to change modes ON OFF OFF OFF Force to Touch Adjust mode Used for touchscreen calibration Reset project memory and settings to default OFF OFF ON OFF Force to Boot ROM Loading Mode OFF OFF...

Page 8: ...hosen another pop up dialog appears as below Users must confirmed the reset again by inputting YES Click OK The default password 111111 is restored However other passwords including download and uploa...

Page 9: ...er Consumption 400 mA 24VDC 340 mA 24VDC 340 mA 24VDC 240 mA 24VDC Protection structure IP65 front panel O ring seal Operating Temperature 0 45 C Operation humidity 10 90 RH non condensing Enclosure P...

Page 10: ...Dimensions Drawings are not to scale and are for visual purposes only Dimensions are in mm inches MMI8100 8104...

Page 11: ...MMI6056 8056 MMI6070H 8070H Kessler Ellis Products 10 Industrial Way East Eatontown NJ 07724 Phone 732 935 1320 Fax 732 935 9344 www kep com 9900132REV15OCT13...