- 10 -
PLASMA 100 Operating Manual
2.02 Specifications
Model PLASMA
100
Input voltage and frequency and phases
380/415V 50/60Hz
KVA @ max output
17.3kVA
Max current
100A
Output current range PCM
20~100A
Open circuit voltage
280/306V
Duty cycle at 40
℃
100%
Weight 60kg
Dimensions 550x300x490
Table 3
2.03 Duty cycle
The duty cycle of a cutting power source is the percentage of a ten (10) minute period that it can be
operated at a given output without causing overheating and damage to the unit. If the cutting amperes
decrease, the duty cycle increases. If the cutting amperes are increased beyond the rated output, the duty
cycle will decrease.
WARNING
: Exceeding the duty cycle ratings will cause the thermal overload
protection circuit to become energized and shut down the output until has cooled
to normal operating temperature
Continually exceeding the duty cycle ratings
can cause damage to the cutting power source.
NOTICE
:
Due to variations that can occur in manufacture products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities and
ratings in use and operation will depend upon correct installation, use, applications, maintenance and service.