The supply must be from an individual grounded circuit that is protected by a circuit breaker
DQGUDWHGSHUWKHVSHFL¿FDWLRQVIRUWKHYDULRXVPRGHOVDVVKRZQLQWKHWDEOHDERYH
Warning: If the electric power supply does not meet the
SURGXFWVSHFL¿FDWLRQVFRQVXOWZLWKDOLFHQVHGHOHFWULFLDQ
before proceeding with installation.
Max Connected
Required Power
Minimum
Kenyon Part # Model #
Load
Supply Input
Wire Size
B41510
MED2
2600 Watts
120 VAC/22A/60Hz
#12 AWG
B41511
MED2
3000 Watts
240 VAC /12.5A/60Hz
#12 AWG
B41515
MED2TL
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B41516
MED2TL
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B41517
MED1
1200 Watts
120 VAC/10A/60Hz
#12 AWG
B41518
MED1
1200 Watts
240 VAC/5A/60Hz
#12 AWG
B41601
CAR2
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B41602
CAR2
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B41603
ARC2
2600 Watts
120 VAC/22A/60Hz
#12 AWG
B41604
ARC2
3000 Watts
240 VAC/12.5A/60Hz
#12 AWG
B41605
CAR1
1200 Watts
120 VAC/10A/60Hz
#12 AWG
B41606
CAR1
1200 Watts
240 VAC/5A/60Hz
#12 AWG
B49510
ALP2LG
2600 Watts
120 VAC/22A/60 Hz
#12 AWG
B49511
ALP2LG
3000 Watts
240 VAC/12.5A/60Hz
#12 AWG
B49512
ANT2
2600 Watts
120 VAC/22A/60Hz
#12 AWG
B49513
ANT2
3000 Watts
240 VAC/12.5A/60Hz
#12 AWG
B49515
ALP2SM
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B49516
ALP2SM
2400 Watts
240 VAC/10A/60Hz
#12 AWG
B49517
ALP1
1200 Watts
120 VAC/10A/60Hz
#12 AWG
B49518
ALP1
1200 Watts
240 VAC/10A/60Hzq
#12 AWG
)RUIXWXUHUHIHUHQFHSOHDVHUHFRUGWKHVHULDOQXPEHURI\RXU
FRRNWRSKHUHBBBBBBBBBBBBBBBBBBBB
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
2