TM-V708A
41
ADJUSTMENT
5. Squelch
check
6. S-meter
write
5) SSG:0.112µV
(-126dBm)
6) Squelch knob:
clockwise MAX
7) Band B (Sub band)
FREQ.:146.050MHz
SSG:OFF
Set to the point where
noise will be erased by
turning the squelch knob.
8) SSG:0.178µV
(-122dBm)
9) Squelch knob:
clockwise MAX
10)Band A (Sub band)
FREQ.:444.150MHz
Set to the point where
noise will be erased by
turning the squelch knob.
11)SSG:0.199µV
(-121dBm)
12)Squelch knob:
clockwise MAX
Switch to adjustment
mode and carry out the
operations for Item B.
Band A
1) FREQ.:146.350MHz
SSG DEV:3kHz
MOD:1kHz
1
S1
SSG:0.28µV (-118dBm)
2
S7
SSG:3.54µV (-96dBm)
2) FREQ.:127.100MHz
SSG DEV:3kHz
MOD:1kHz
1
S1
SSG:0.28µV (-118dBm)
2
S7
SSG:3.54µV (-96dBm)
3) FREQ.:223.100MHz
SSG DEV:3kHz
MOD:1kHz
1
S1
SSG:0.707µV (-110dBm)
2
S7
SSG:7.94µV (-89dBm)
Squelch open.
BUSY lights on.
AF output disappear.
BUSY lights off.
SQL knob position:
8:00 ~ 11:00
BUSY lights off.
Squelch open.
BUSY lights on.
AF output disappear.
BUSY lights off.
SQL knob position:
8:00 ~ 11:00
BUSY lights off.
Squelch open.
BUSY lights on.
AF output disappear.
BUSY lights off.
One Segment in
S-meter lights.
All segments in
S-meter light.
One Segment in
S-meter lights.
All segments in
S-meter light.
One Segment in
S-meter lights.
All segments in
S-meter light.
SSG
Rear
ANT
Oscilloscope panel
EXT.SP
SSG
Rear
ANT
panel
Display
Check
Check
Check
Display
[S1] key
Write
[S7] key
[S1] key
[S7] key
[S1] key
[S7] key
Item
Condition
Measurement
Receiver section
Adjustment
Specifications/
Remarks
Test-
Unit
Terminal
equipment
Unit
Parts
Method