TM-281A
28
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
3. Squelch
Open
•
Wide
[Low]
1) Adj item: [SQOL.]
2) SSG output
: –124dBm (0.14µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
SSG
Oscilloscope
AF VM
Distortion
meter
Rear
panel
ANT
EXT. SP
Front
panel
Tuning
control
Write
[Center]
3) Adj item: [SQOC.]
Adjust:
[
✳✳
]
4) SSG output
: –124dBm (0.14µV)
[High]
5) Adj item: [SQOH.]
Adjust:
[
✳✳
]
6) SSG output
: –124dBm (0.14µV)
• Narrow
[Center]
7) Adj item: [SQOC.]
(“N” icon apper)
Adjust:
[
✳✳
]
8) SSG output
: –124dBm (0.14µV)
SSG MOD: 1kHz
SSG DEV: 1.5kHz
4. RSSI writing 1) Frequency: 155.050MHz
2) SSG output: –53dBm (501µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
RSSI value writing
is performed by the
“Squelch open”
item (center wide).
SSG output level
is changed and ad-
justed after Squelch
adjustment.
This adjustment
should not turn the
Tuning control.
5. S-meter
S1
1) Adj item: [S1.]
Adjust:
[
✳✳
]
2) SSG output
: –118dBm (0.28µV)
SSG MOD: 1kHz
SSG DEV: 3kHz
Write
6. S-meter
Full
scale
1) Adj item: [S7.]
Adjust:
[
✳✳
]
2) SSG output
: –96dBm (3.54µV)
SSG MOD: 1kHz
SSG DEV: 3kHz