ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
48
TK-980/981
3. High power
1) Set test mode
Power meter Rear
ANT
15.0W
±
1.0W
Select “POW” in tuning mode. F. counter panel
“L POW”
PTT : ON
2) “C POW”
PTT : ON
3) “H POW”
PTT : ON
4. TA power
1) Set test mode
Power meter
13.0W
±
1.0W
Select “L POW” in tuning mode.
“L TPOW”
PTT : ON
2) “C TPOW”
PTT : ON
3) “H TPOW”
PTT : ON
5. Power check 1) Set test mode
Power meter
ANT
Check
15W
±
1W
CH : CH1 - Sig1
7A or less
CH4 - Sig1
Ammeter
DC IN
CH7 - Sig1
PTT : ON
6. Modulation
1) Set test mode
Power meter Rear
ANT
Make the de-
balanced
MIC input : OFF
Deviation
panel
modulation
Select “BAL” in tuning mode. meter
waveform neat.
“L BAL”
Oscilloscope
Deviation meter filter
LPF : 3kHz, HPF : OFF
AF VTVM
Front
MIC
De-emphasis : OFF
AG
panel
2) “C BAL”
PTT : ON
3) “H BAL”
PTT : ON
7. Maximum
1) Set test mode
3.8kHz (TK-980)
±
50Hz
deviation
Connect AG to the MIC terminal.
1.75kHz (TK-981)
Select “MAX” in tuning mode.
(According to the
“L MAX”
, –)
AG : 1kHz/50mV
Deviation meter filter
LPF : 15kHz, HPF : OFF
De-emphasis : OFF
PTT : ON
2) “C MAX”
PTT : ON
3) “H MAX”
PTT : ON
8. NPSPAC
1) Set test mode
2.9kHz (TK-980)
±
50Hz
maximum
Connect AG to the MIC terminal.
(According to the
deviation
Select “NMAX” in tuning mode.
, –)
“L NMAX”
AG : 1kHz/50mV
Deviation meter filter
LPF : 15kHz, HPF : OFF
De-emphasis : OFF
PTT : ON
2) “C NMAX”
PTT : ON
3) “H NMAX”
PTT : ON