8
Programming the Talk Group information for a 2016 Base
The 2016 base modem operates differently than the 2012/Merlin mobile unit. As the
2012/Merlin changes talk groups for d ata and voice, the 2016 requires the radio to be
only programmed with the data talk group. This makes the base TK -x80 radio in to a
stand-alone data radio. No voice is to be used on the base TK -x80 connected to the 2016.
To program the talk group data for a 2016 interface simply add one system and one group
to the radio, and do not define any talk group for data. The figure below illustrates a
typical talk group setup for a 2016 base unit.
+------------------------------------------------------------ ------------------ +
¦ System No. : 1 Trunking Mode ¦
¦------------------------------------------------------------------------------ ¦
¦ Grp Option ¦
¦ Grp EncID DecID Grp -Name Call Pwr Transpond LOut Signal TA ¦
¦ 1 151 151 Data Chan No Hi No No None No ¦
¦ 2 ¦
¦ 3 ¦
¦ 4 ¦
¦ 5 ¦
¦ 6 ¦
¦ 7 ¦
¦ 8 ¦
¦ 9 ¦
¦ 10 ¦
+------------------------------------------------------------------------------ +
In programming the 2012/Merlin mobile data terminal, it was required that you define the
talk group as a data talk group. When programming for a 2016 base unit, data definition
should be turned
off
in both the
F9
and
F10
(
System
and
Group Information)
screens.
Use your cursor to select the talk group and press the
F9 key
. The figure below shows a
typical configuration of the
F9
(
System Data
) screen.
+------------------------------------- +
¦ System Data ¦
¦------------------------------------- ¦
¦ System Name : [ 1 ] ¦
¦ System Lockout : [***] ¦
¦ Scan Weight : [*] ¦
¦ Auto TEL Search : [No ] ¦
¦ TA Busy Ch LOut : [No ] ¦
¦ Wide/Narrow : [Wide ] ¦
¦ Fix ID 1st 2nd ¦
¦ ID : [ ] [ ] ¦
¦ Call Indicator : [***] [***] ¦
¦ Horn Alert : [***] [***] ¦
¦ Opt Signalling : [****] [****] ¦
¦ Block ID's Start Stop ¦
¦ Telephone : [ - ] ¦
¦ TX Inhibit : [ - ] ¦
¦ Decode : [ - ] ¦
¦ Data System/Group : [ - ] ¦
¦ Data Delay Time : [ 15]ms ¦
+------------------------------------- +
Single talk group operation. This talk
group is for data only
Option Signal should
be set to None
Data System/Group