ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
5. DQT
Balance
(Narrow)
1) TEST CH: Low, Low’, Center,
High’, High (5 points)
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) Transmit
Deviation
meter
ANT
FPU
The Deviation of
20Hz frequency
is fi xed. (FL=30,
FLC=35, FC=40,
FCH=45, FH=50)
Change the 1kHz
adjustment value to
become the same
deviation of 20Hz
within the specifi ed
range.
±0.4dB
6. Maximum
Deviation
(Narrow)
1) TEST CH: Low, Low’, Center,
High’, High (5 points)
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
Deviation
meter
Oscillo-
scope
AG
AF VTVM
ANT
2.2kHz
(According to the
large +, –)
±0.05kHz
Note:
FPU auto input 1kHz/50mV
7. MIC
Sensitivity
Check
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
ANT
MIC
Check
1.1kHz~1.8kHz
8. DQT
Deviation
(Narrow)
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
AG:
11kHz/5mV
3) Transmit
ANT
FPU
0.35kHz
±0.05kHz
9. QT
Deviation
(Narrow)
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 3kHz
HPF: OFF
3) Transmit
0.35kHz
±0.05kHz
10. DTMF
Deviation
(Narrow)
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
1.5kHz
±0.05kHz
11. MSK
Deviation
(Narrow)
1) TEST CH: Center
2) Deviation meter fi lter
LPF: 15kHz
HPF: OFF
3) Transmit
1.5kHz
±0.05kHz
Receiver Section
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
1. Sensitivity
(Semiauto-
matic)
1) TEST CH: Low, Low’, Center,
High’, High (5 points)
2) SSG output: –90dBm (7.08µV)
Mod:
1kHz
Dev:
±1.5kHz
SSG
Oscillo-
scope
AF VTVM
Distortion
meter
ANT
Ext.SP
FPU
Auto tuning
TENTATIVE