79
78
LEVEL DIAGRAM
Receiver Section
Center Frequency
49.95MHz
450kHz
Audio Frequency
Control Unit
TX-RX Unit
VCO Unit
TX-RX Unit
Power Module
TX-RX Unit
To make measurements in the RF section, connect the RF
level meter.
In the RF section, use a 0.01
µ
F coupling capacitor.
(The display shows the SSG input value required to obtain
12dB SINAD.)
To make measurements in the AF section, connect the AC level meter.
(ANT input : –53dBm, 1kHz FM, 3kHz DEV (Wide) / 2.4kHz DEV (Semi wide) / 1.5kHz DEV (Narrow))
The AF output level is adjusted for 0.45V/4
Ω
by the front panel AF VOL control.
To make measurements in
the RF section, connect the
RF wattmeter (50
Ω
).
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/2.4kHz/1.5kHz (Wide/Semi wide/Narrow) DEV at 1kHz MOD.
W/N 5.0mVrms
SW
4.0mVrms
W/N 11.2mVrms
SW
8.96mVrms
W/N 450mVrms
SW
360mVrms
W
120mVrms
SW
96mVrms
N
58mVrms
Transmitter Section
TK-760G/
(
N
)
/762G/
(
N
)
TK-760G/
(
N
)
/762G/
(
N
)