ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
60
TK-690H
(
B
)
11. DQT
1) CH-SIG : 1-2
Power meter Rear
ANT
Panel
PF3 key Make the
Flat the a parts.
balance
Select BLNC_XXX
Deviation
PF4 key demodulation wave-
in tune mode
meter
form neat.
PTT : ON
AF VTVM
Panel
MIN
Deviation meter filter
AG
HPF : OFF
Oscilloscope
LPF : 3kHz
De-emphasis : OFF
12. QT
1) CH-SIG : 1-4
±
0.75kHz
±
0.05kHz
deviation
Select QTDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
13. DQT
1) CH-SIG : 1-6
±
0.75kHz
±
0.05kHz
deviation
Select DQDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
14. DTMF
1) CH-SIG : 1-8
±
3.0kHz
±
0.1kHz
deviation
Select DTDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
15. MSK
1) CH-SIG : 1-9
±
3.0kHz
±
0.1kHz
deviation
Select MSDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
16. Sensitivity
1) Select _ _L
SSG
Rear
ANT
Panel
PF3 key Low check
SINAD 12dB or more
SENS_XXX
PF4 key
in tune mode
AF VTVM
EXT.SP
SSG output : –116dBm/0.35
µ
V Distortion
TX-RX
L124
AF output : 1V/4
Ω
meter
(A/2)
Oscilloscope
2) Select _ _C
4
Ω
dummy
Center check
SENS_XXX
load
in tune mode
3) Select _ _H
High check
SENS_XXX
in tune mode
A