59
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-690H
(
B
)
6. MCF
1) CH-SIG : 1-1
Spectrum
TX-RX
CN103
TX-RX
L133
Adjust it so it is almost symmetrical, and so the
Spectrum analyzer
analyzer
(A/2)
(A/2)
L132
gain is maximum.
Span : 25kHz
L131
Adjust the coils in the following order : L133, L132,
Scale : 2dB div
Tracking
CN102
L129
L131, L129, L128.
Center frequency : 10.70MHz generator
L128
Tracking generator
Output : –20dBm
7. Distortion
1) CH-SIG : 1-1
SSG
Rear
ANT
Check
3% or less
SSG output : –53dBm/501
µ
V
Distortion
EXT.SP
If the distortion value exceeds
AF output : 1V/4
Ω
meter
3%, you must adjust L129
AF VTVM
to obtain a minimum
Oscilloscope
distortion value.
4
Ω
dummy
load
8. RF power
1) CH-SIG : 1-1
Power meter Rear
ANT
Final
VR1
Maximum clockwise 115W or more
(High power)
Select _POW_XXX
Ammeter
in tune mode
110W adj.
110W
±
5W, 20A or less
PTT : ON
Panel
PF3 key Check
110W
±
1W
PF4 key
(Low power) 1) CH-SIG : 1-1
45W adj.
45W
±
1W
Select LPOW_XXX
in tune mode
PTT : ON
9. Maximum
1) Select _ _L
Power meter Rear
ANT
Panel
PF3 key
±
4.05kHz
±
0.05kHz
deviation
MXDV_XXX
Deviation
PF4 key
in tune mode
meter
PTT : ON
AF VTVM
Panel
MIC
Deviation meter filter
AG
HPF : OFF
Oscilloscope
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/50mV
2) Select _ _C
MXDV_XXX
in tune mode
PTT : ON
3) Select _ _H
MXDV_XXX
in tune mode
PTT : ON
10. MIC
1) CH-SIG : 1-1
TX-RX
VR501 Check
2.75~3.25kHz
sensitivity
PTT : ON
(B/2)
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/5mV
REF 0dBm
2dB/
RBW
3kHz
VBW
1kHz
SWP
100m
s
SPAN 25kHz
CENTER 10.7MHz
ATT 10dBm
MAR
10kHz
2dB
max.
5kHz
5kHz
10.695MHz
10.69MHz
10.705MHz
10.71MHz
10dB or more
(
±
10kHz)