ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
48
TK-390
4. Sensitivity
1) Set panel test mode
SSG
Panel
ANT
Panel
Top1/
Adjust for maximum 12dB SINAD or more
adjustment
CH No. : 3
Top2
SINAD
and check
Signalling No. : 1
AF VTVM
Side
Universal
(wide)
Select SNS
✽ ✽ ✽
Oscilloscope
in panel tuning mode
Distortion
Push Orange to 3 point
meter
adjustment mode
Audio
Select SNS
✽ ✽ ✽
analyzer
L
SSG freq. : Low
output : –116dBm/0.35
µ
V
2) Push Side2 to select
SNS
✽ ✽ ✽
M
SSG freq. : Center
3) Push Side2 to select
SNS
✽ ✽ ✽
H
SSG freq. : Hi
5. Sensitivity
1) Set panel test mode
Check
12dB SINAD or more
check
CH No. : 1
(narrow)
Signalling No. : 1
SSG output : –116dBm/0.35
µ
V
MOD. : 1kHz
DEV. : 1.5kHz
Turn the toggle SW to the
right (narrow)
2) Set panel test mode
CH No. : 3
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
3) Set panel test mode
CH No. : 5
Signalling No. : 1
Turn the toggle SW to the
right (narrow)
6. Tight
1) Set panel test mode
Panel
Top1/
Adjust to point of
squelch
CH No. : 3
Top2
opening squelch
adjustment
Signalling No. : 1
(wide)
Select SQ T
✽ ✽ ✽
in panel tuning mode
SSG output : 6dB above to
12dB SINAD level.
7. Tight
1) Set panel test mode
squelch
CH No. : 3
adjustment
Signalling No. : 1
(narrow)
Select SQ T
✽ ✽ ✽
in panel tuning mode
Turn the toggle SW to the
right (narrow)
SSG output : 6dB above to
12dB SINAD level.
8. Squelch
1) Set panel test mode
Adjust to point of
adjustment
CH No. : 3
opening squelch
(wide)
Signalling No. : 1
Select SQ O
✽ ✽ ✽
in panel tuning mode
SSG output : 3dB below to
12dB SINAD level