ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
44
TK-390
8. Maximum
1) Set panel test mode
Power meter Panel
ANT
Panel
Top1/
3.95kHz
±
50Hz
deviation
CH No. : 3
Deviation
Top2
(According to the
adjustment
Signalling No. : 1
meter
, –)
(Wide)
Select MDV
✽ ✽ ✽
Oscilloscope
in panel tuning mode
Push Orange to 3 point
AG
Side
Universal
adjustment mode
AF VTVM
Select MDV
✽ ✽ ✽
L
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Push Side2 to select
MDV
✽ ✽ ✽
M
PTT : ON
3) Push Side2 to select
MDV
✽ ✽ ✽
H
PTT : ON
9. Maximum
1) Set panel test mode
1.90kHz
±
50Hz
deviation
CH No. : 3
(According to the
adjustment
Signalling No. : 1
, –)
(narrow)
Select MDV
✽ ✽ ✽
in panel tuning mode
Turn the toggle SW to the
right (narrow).
Push Orange to 3 point
adjustment mode
Select MDV
✽ ✽ ✽
N L
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Push Side2 to select
MDV
✽ ✽ ✽
N M
PTT : ON
3) Push Side2 to select
MDV
✽ ✽ ✽
N H
PTT : ON
10. MIC
1) Set panel test mode
Check
1.8kHz~3.6kHz
sensitivity
CH No. : 3
check
Signalling No. : 1
AG : 1kHz/15mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
2) Turn the toggle SW to the
0.9kHz~1.8kHz
right (narrow)
PTT : ON