TK-360G/(N)/370G/(N)
44
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
Fig. 1
Fig. 2
E4, (N)E4 type
1. Sensitivity
Adj item [SENS]
DVM
Encoder knob
f
L
: ([S
.
E N S]) : [55]
Adjustment Adjust [
∗∗∗
]
f
C
: (S
.
E
.
N
.
S) : [125]
f
L
f
c
f
H
[S
.
E N S]
➞
[S
.
E
.
N
.
S]
➞
[S
.
E
.
N
.
S
. .
]
f
H
: (S
.
E
.
N
.
S
. .
) : [190]
2. BPF
(PANEL TEST MODE)
Tracking generator
ANT
TC301, TC302,
Adjust wave form
CH-Sig 2-1
spectrum analyzer
TC303
to figure 1.(f
L
)
Tra-G setting -40dBm
BPF
CH-Sig 1-1
Check wave form to figure 2.(f
C
)
CH-Sig 3-1
Check wave form to figure 2.(f
H
)
3. Sensitivity
[Panel Test Mode]
SSG
ANT
Check
1) CH-Sig:1-1
AF VTVM
Check
12dB SINAD or
SSG OUT
Oscilloscope
more
Wide:-118dBm
(MOD:1kHz /
±
3kHz)
Narrow:-116dBm
(MOD:1kHz /
±
1.5kHz)
4. Squelch (Open) 1) Adj item [SQL3]
Encoder
Adjust to the
Adjust
Adjust [
∗∗∗
]
knob
squelch
[Wide 5K]
SSG OUT:-123dBm 360G E4
squelch.
threshold point
[Wide 4K]
SSG OUT:-123dBm 360G E4
E4
[Narrow]
2) Adj item [SQL3.]
(N)E4
Adjust [
∗∗∗
]
SSG OUT:-122dBm 360G (N)E4
5. Squelch(Tight) 1) Adj item [SQL9]
Adjust to the
Adjust
Adjust [
∗∗∗
]
squelch
[Wide 5K]
SSG OUT:-116dBm 360G E4
threshold point
[Wide 4K]
SSG OUT:-116dBm 360G E4
[Narrow]
2) Adj item [SQL9.]
SSG OUT:-110dBm 360G (N)E4
6. Squelch
[Panel Test Mode]
Check
Squelch must
Check
1) CH-Sig:1-1
be opened.
SQ Level : [SQL5]
SSG OUT:
-118dBm
2) SSG OUT:OFF
Squelch must
be closed.