background image

TK-3230

2

ADJUSTMENT

Required Test Equipment

1. Stabilized Power Supply

1) The supply voltage can be changed between 0V and 10V, 

and the current is 3A or more

2) The standard voltage is 3.8V

2. DC Ammeter

1) Class 1 ammeter (17 ranges and other features).
2) The full scale can be set to either 300mA or 3A.
3) A cable of less internal loss must be used.

3. Frequency Counter (f. counter)

1) Frequencies of up to 1GHz or so can be measured.
2)  The sensitivity can be changed to 500MHz or below, and 

measurements are highly stable and accurate (0.2ppm or so).

4. Power Meter

1) Measurable frequency : Up to 600MHz
2) Impedance : 50

Ω

, unbalanced

3) Measuring range : Full scale of 3W or so
4) A standard cable (5D2W 1m) must be used.

5. RF Voltmeter (RF V.M)

1) Measurable frequency : Up to 600MHz or so

6. Linear Detector

1) Measurable frequency : Up to 600MHz or so
2) Characteristics are fl at, and CN is 60dB or more

7. Digital Voltmeter

1) Voltage range : FS=10V or so
2) Input resistance : 1M

Ω

 or more

8. Oscilloscope

1) Measuring range : DC to 30MHz
2) Provides highly accurate measurements for 5 to 25MHz.

9. AF Voltmeter (AF V.M)

1) Measurable frequency : 50Hz to 1MHz
2) Maximum sensitivity : 1mV or more

10. Standard Signal Generator (SSG)

1) Maximum frequency : 600MHz or more
2) Output : –133dBm/0.05µV to 7dBm/501mV
3) Output impedance : 50

Ω

11. Dummy Load

1) 8

Ω

, 1W or more

12. AF Generator (AG)

1) Frequency range : 100Hz to 100kHz
2) Output : 0.5mV to 1V

13. Distortion Meter

1) Measurable frequency : 30Hz to 100kHz
2) Input level : 50mV to 10Vrms

Service Jig

 ANT cable (E30-3418-08)

Modify the cable as shown below.

Cut

Solder the ANT cable to  the ANT terminal on the TX-RX 

unit.

GND

ANT

terminal

TX-RX unit

ANT cable

 Battery jig (W05-1365-00)

Connect the power cable properly between the battery 

jig installed in the transceiver and the power supply, and 
be sure output voltage and the power supply polarity prior 
to switching the power supply ON, otherwise over voltage 
and reverse connection may damage the transceiver, or the 
power supply or both.

Note:

 When using the battery jig, you must measure the 

voltage at the terminals of the battery jig. Otherwise, a 
slight voltage drop may occur within the power cable, 
between the power supply and the battery jig, especially 
while the transceiver transmits.

Test Signaling

No.

Receive

Transmit

1

None

None

2

None

100Hz Square Wave

3

QT 67.0Hz

QT 67.0Hz

4

QT 151.4Hz

QT 151.4Hz

5

QT 250.3Hz

QT 250.3Hz

6

DQT D023N

DQT D023N

7

DQT D754I

DQT D754I

8

MSK Code (100-1000)

MSK Code (100-1000)

9

None

MSK (1010…)

Test Frequency

No.

Receive (MHz)

Transmit (MHz)

1 (Low)

460.05000 

460.10000 

2 (High)

469.95000 

469.90000 

3

460.00000 460.00000 

4

460.20000 460.20000 

5

460.40000 460.40000 

6

460.60000 460.60000 

Adjustment Frequency List

CH

Receive (MHz)

Transmit (MHz)

Center

465.05000 465.00000 

Frequency Shift 6.25kHz

-

465.00625 

Frequency Shift 5.kHz

-

465.00500

Summary of Contents for TK 3230 - FreeTalk XLS UHF

Page 1: ...ice manual in place of the adjustment items in the TK 3230 B51 8792 00 service manual Document Copyrights Copyright 2007 by Kenwood Corporation All rights reserved No part of this manual may be reproduced translated distributed or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise for any purpose without the prior written permission of Kenwood Disclai...

Page 2: ...1W or more 12 AF Generator AG 1 Frequency range 100Hz to 100kHz 2 Output 0 5mV to 1V 13 Distortion Meter 1 Measurable frequency 30Hz to 100kHz 2 Input level 50mV to 10Vrms Service Jig ANT cable E30 3418 08 Modify the cable as shown below Cut Solder the ANT cable to the ANT terminal on the TX RX unit GND ANT terminal TX RX unit ANT cable Battery jig W05 1365 00 Connect the power cable properly betw...

Page 3: ...nter ANT Jig cable SP MIC jack PC key Adjust to the center frequency Within 100Hz 2 Frequency shift 6 25kHz 1 PC tune CH TX 460 00625MHz PTT ON Adjust to the desired frequency Within 100Hz 3 Frequency shift 5kHz 1 PC tune CH TX 460 005MHz PTT ON 4 High transmit power 1 PC tune CH TX center Power meter DC ammeter Adjust it to 1 5W 0 1W Less than 1 6A 2 Test mode CH TX low high PTT ON Check 1 15 1 8...

Page 4: ...Linear detector filter LPF 3kHz PTT ON Linear detector PC key Adjust it to 0 75kHz 0 05kHz 2 PC tune CH TX center Narrow QT 151 4Hz Linear detector filter LPF 3kHz PTT ON Adjust it to 0 35kHz 0 05kHz 10 DQT fine deviation 1 PC tune CH TX center Wide DQT 023N Linear detector filter LPF 3kHz PTT ON Adjust it to 0 75kHz 0 05kHz 2 PC tune CH TX center Narrow DQT 023N Linear detector filter LPF 3kHz PT...

Page 5: ... 35µV SSG MOD 1kHz SSG DEV 1 5kHz 2 Squelch level open 1 PC tune CH RX center Wide SSG output 121dBm SSH MOD 1kHz SSG DEV 3 0kHz PC key Adjust to open the squelch 2 PC tune CH RX center Narrow SSG output 120dBm SSH MOD 1kHz SSG DEV 1 5kHz Adjustment Points PTT TXD LCD ANT 3C 3T LV RSSI BUSY 3M TX RX unit Component side BATT INT SP INT SP SB BATT VR301 S1 PTT J300 EXT SP MIC VR300 TX RX unit Foil s...

Page 6: ...Singapore 569110 CA 90801 5745 U S A Kwai Fong N T Hong Kong WD18 9EB United Kingdom L Etoile Paris Nord 2 50 Allée des Impressionnistes Bp 58416 Villepinte 95944 Roissy Ch De Gaulle Cedex TK 3230 General Frequency Range BRS Preset 56CH LMR 460 to 470MHz Number of Channels 2CH FPU 16CH PLL Channel Stepping 6 25kHz 5kHz Modulation Wide Narrow 16K0F3E 11K00F3E RF Output Power High Low 1 5W 500mW Ope...

Reviews: