![Kenwood TK-3200L Service Manual Download Page 19](http://html.mh-extra.com/html/kenwood/tk-3200l/tk-3200l_service-manual_191507019.webp)
TK-3200L
18
5.Max deviation TEST CH: Center
Power meter
ANT
Programming
4.2kHz
±80Hz
Adjust
Low
Deviation meter
SP/MIC connector
Software:KPG-88D (According to
[Wide]
High
Oscilloscope
the ,–)
(3 points)
AG
AG:1kHz/150mV
AF VTVM
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
2.2kHz
±80Hz
PTT:ON
(According to
the ,–)
6.VOX 1
TEST CH: Center
Writing
AG:1kHz/45mV
7.QT deviation
TEST CH: Center
ANT
Programming
0.80kHz
±40Hz
Adjust
Low
Software:KPG-88D
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
0.40kHz
±40Hz
PTT:ON
8.DQT deviation
TEST CH: Center
0.75kHz
±40Hz
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
0.40kHz
±40Hz
PTT:ON
9.DTMF deviation TEST CH:Center
3.0kHz
±100Hz
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
1.5kHz
±100Hz
PTT:ON
10.MSK deviation TEST CH: Center
3.0kHz
±100Hz
Adjust
Low
[Wide]
High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
1.5kHz
±100Hz
PTT:ON
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark