TK-3160
40
7.DQT TCXO
TEST CH:Center
Power meter
ANT
Programming
Write
200 hex
Balance Writing
Dev meter
Software:KPG-82D
[Wide]
Oscilloscope
[Narrow]
AG
120 hex
8.DQT VCO
TEST CH: Low
AF VTVM
Make the
Balance
Center
demodulation
Adjust
High
wave into
[Wide]
(3 points)
square waves
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
9.QT Deviation TEST CH:Low
0.8kHz
±40Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
0.4kHz
±40Hz
PTT:ON
10.DQT Deviation TEST CH: Low
0.75kHz
±40Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
0.35kHz
±40Hz
PTT:ON
11.Tone Deviation TEST CH:Center
3.0kHz
±100Hz
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
1.5kHz
±100Hz
PTT:ON
12.DTMF Deviation TEST CH:Center
3.0kHz
±100Hz
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
1.5kHz
±100Hz
PTT:ON
13.MSK Deviation TEST CH: Low
3.0kHz
±100Hz
Adjust
Center
[Wide]
High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
1.5kHz
±100Hz
PTT:ON
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark