TK-290-11B
21
Item
Condition
Measurement
Adjustment
Specifications/Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
1. AF level
1) Set panel test mode
SSG
Panel
ANT
Check
0.55V
±
0.3V (VOL. 2)
check
CH No. : 3
5% or less
Signaling No. : 1
AF VTVM
Side
Universal
SSG freq. : Each freq.
Oscilloscope
output : –53dBm/501
µ
V
Distortion
MOD. : 1kHz
meter
DEV. : 2.4kHz
Audio
analyzer
2. Hum and
1) Set panel test mode
37dB or more
noise ratio
CH No. : 3
check
Signaling No. : 1
SSG output : –53dBm/501
µ
V
3. BPF coil
1) Set panel test mode
Tracking
Panel
ANT
TX-RX
L201
Adjust the BPF coil so that the waveform is peaked.
CH No. : 1
generator
L202
The frequency with the peak waveform does not
Use this
Connect the spectrum
L205
have to be the center frequency.
adjustment
analyzer to TP3.
Spectrum
TX-RX
TP3
L206
After finished peaking the waveform, perform a
procedure
Signaling No. : 1
analyzer
3 point adjustment and set for maximum sensitivity.
after replace-
Push Monitor to 3 point
ing any of
adjustment mode
the BPF
Select SNS
75
coils
MON
4. Sensitivity
1) Set panel test mode
SSG
Panel
ANT
Panel
SW A/
Adjust for maximum 12dB SINAD or more
adjustment
CH No. : 3
SW B
SINAD
and check
Signaling No. : 1
AF VTVM
Side
Universal
Select SNS
∗∗∗
Oscilloscope
in panel tuning mode
Distortion
Push Monitor to 3 point
meter
adjustment mode
Audio
Select SNS
∗∗∗
analyzer
L MON
SSG freq. : Low
output : –116dBm/0.35
µ
V
2) Push Tone 2 to select
SNS
∗∗∗
C MON
SSG freq. : Center
3) Push Tone 2 to select
SNS
∗∗∗
H MON
SSG freq. : Hi
5. Tight
1) Set panel test mode
Adjust to point of
squelch
CH No. : 3
opening squelch
adjustment
Signaling No. : 1
Select SQ T
∗∗∗
in panel tuning mode
SSG output : 3dB above to
12dB SINAD level.
RX BPF 010.011
REF –10.0dBm
10dB/
ATT 10dB
A write B blank
RBW
100kHz
VBW
10kHz
SWP
200ms
CENTER 155.0MHz
SPAN 100.0MHz
TG LEVEL
–30dBm
Hi
Center
Low
MKR
155.4MHz
–27.20dBm
Receiver Section