TK-3501
2
GENERAL
INTRODUCTION
SCOPE OF THIS MANUAL
This manual is intended for use by experienced techni-
cians familiar with similar types of commercial grade com-
munications equipment. It contains all required service
information for the equipment and is current as of the pub-
lication date. Changes which may occur after publication
are covered by either Service Bulletins or Manual Revisions.
These are issued as required.
ORDERING REPLACEMENT PARTS
When ordering replacement parts or equipment informa-
tion, the full part identification number should be included.
This applies to all parts : components, kits, or chassis. If the
part number is not known, include the chassis or kit number
of which it is a part, and a sufficient description of the re-
quired component for proper identification.
PERSONAL SAFETY
The following precautions are recommended for personal
safety:
• DO NOT transmit until all RF connectors are verified
secure and any open connectors are properly terminated.
• SHUT OFF and DO NOT operate this equipment near
electrical blasting caps or in an explosive atmosphere.
• This equipment should be serviced by a qualified techni-
cian only.
SERVICE
This transceiver is designed for easy servicing. Refer
to the schematic diagrams, printed circuit board views, and
alignment procedures contained within.
Document Copyrights
Copyright 2014 by JVC KENWOOD Corporation. All
rights reserved.
No part of this manual may be reproduced, translated,
distributed, or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording, or other-
wise, for any purpose without the prior written permission of
JVC KENWOOD Corporation.
Disclaimer
While every precaution has been taken in the preparation
of this manual, JVC KENWOOD Corporation assumes no
responsibility for errors or omissions. Neither is any liability
assumed for damages resulting from the use of the informa-
tion contained herein. JVC KENWOOD Corporation reserves
the right to make changes to any products herein at any time
for improvement purposes.
Channel No.
FREQUENCY
Signaling
Output Power
1
446.00625MHz
94.8Hz
2
446.09375MHz
88.5Hz
3
446.03125MHz
103.5Hz
4
446.06875MHz
79.7Hz
5
446.04375MHz
118.8Hz
6
446.01875MHz
123.0Hz
7
446.08125MHz
127.3Hz
ERP 0.5W
8
446.05625MHz
85.4Hz
9
446.00625MHz
107.2Hz
10
446.09375MHz
110.9Hz
11
446.03125MHz
114.8Hz
12
446.06875MHz
82.5Hz
13
446.04375MHz
D132N
14
446.01875MHz
D155N
15
446.05625MHz
D134N
16
446.08125MHz
D243N
■
Defauit channel list