Kenwood PKT-23K Easy Programming Instructions Download Page 13

Self Programming Mode

Self Programming Timer is 20 seconds

Channel

#

QT/DQT

Table 

No.

Tone

1

QT

1

67.0 Hz

2

QT

1

67.0 Hz

3

QT

1

67.0 Hz

4

QT

1

67.0 Hz

No.

QT

No.

QT

No.

QT

1

67

16

114.8

31

192.8

2

71.9

17

118.8

32

203.5

3

74.4

18

123

33

210.7

4

77

19

127.3

34

218.1

5

79.7

20

131.8

35

225.7

6

82.5z

21

136.5

36

233.6

7

85.4

22

141.3

37

241.8

8

88.5

23

146.2

38

250.3

9

91.5

24

151.4

39

69.3

10

94.8

25

156.7

40

Custom

11

97.4

26

162.2

41

Custom

12

100

27

167.9

42

Custom

13

103.5

28

173.8

43

Custom

14

107.2

29

179.9

44

Custom

15

110.9

30

186.2

45

Custom

No.

DQT

No.

DQT

No.

DQT

No.

DQT

No.

DQT

No.

DQT

1

D023N

30

D205N

59

D465N

88

D031I

117

D243I

146

D506I

2

D025N

31

D223N

60

D466N

89

D032I

118

D244I

147

D516I

3

D026N

32

D226N

61

D503N

90

D043I

119

D245I

148

D532I

4

D031N

33

D243N

62

D506N

91

D047I

120

D251I

149

D546I

5

D032N

34

D244N

63

D516N

92

D051I

121

D261I

150

D565I

6

D043N

35

D245N

64

D532N

93

D054I

122

D263I

151

D606I

7

D047N

36

D251N

65

D546N

94

D065I

123

D265I

152

D612I

8

D051N

37

D261N

66

D565N

95

D071I

124

D271I

153

D624I

9

D054N

38

D263N

67

D606N

96

D072I

125

D306I

154

D627I

10

D065N

39

D265N

68

D612N

97

D073I

126

D311I

155

D631I

11

D071N

40

D271N

69

D624N

98

D074I

127

D315I

156

D632I

12

D072N

41

D306N

70

D627N

99

D114I

128

D331I

157

D654I

13

D073N

42

D311N

71

D631N

100

D115I

129

D343I

158

D662I

14

D074N

43

D315N

72

D632N

101

D116I

130

D346I

159

D664I

15

D114N

44

D331N

73

D654N

102

D125I

131

D351I

160

D703I

16

D115N

45

D343N

74

D662N

103

D131I

132

D364I

161

D712I

17

D116N

46

D346N

75

D664N

104

D132I

133

D365I

162

D723I

18

D125N

47

D351N

76

D703N

105

D134I

134

D371I

163

D731I

19

D131N

48

D364N

77

D712N

106

D143I

135

D411I

164

D732I

20

D132N

49

D365N

78

D723N

107

D152I

136

D412I

165

D734I

21

D134N

50

D371N

79

D731N

108

D155I

137

D413I

166

D743I

22

D143N

51

D411N

80

D732N

109

D156I

138

D423I

167

D754I

23

D152N

52

D412N

81

D734N

110

D162I

139

D431I

168

D645I

24

D155N

53

D413N

82

D743N

111

D165I

140

D432I

169

Custom

25

D156N

54

D423N

83

D754N

112

D172I

141

D445I

170

Custom

26

D162N

55

D431N

84

D645N

113

D174I

142

D464I

171

Custom

27

D165N

56

D432N

85

D023I

114

D205I

143

D465I

172

Custom

28

D172N

57

D445N

86

D025I

115

D223I

144

D466I

173

Custom

29

D174N

58

D464N

87

D026I

116

D226I

145

D503I

174

Custom

Summary of Contents for PKT-23K

Page 1: ...Kenwood U S A Communications Sector PKT 23 UHF Ultra Small Compact Portable Radio Copyright 2013 JVC KENWOOD Corporation All rights reserved EASY PROGRAMMING INSTRUCTIONS ...

Page 2: ...and DQT 168 Coded Squelch 2 Programmable Function Keys Channel Scan Super Lock Manager Key Lock Voice Guided Self Programming Mode Bell Tone Alert VOX Ready Wireless Clone Built in 1 430mAh Li ion Battery 3 Hour Fast Charger KSC 44 Spring Action Belt Clip KBH 20 1 5W 99 UHF BRS Frequencies Preprogrammed 2 year Warranty ...

Page 3: ...iles 8 km Residential areas near building Up to 1 5miles 2 4 km In steel and or concrete reinforced building Up to 225 000sq ft 20 900sq m In high rise buildings Up to 17 floors Battery Life 5 5 90 duty cycle Without Audio Accessory Saver off 11 hours Saver on 15 hours With Audio Accessory Saver off 12 hours Saver on 17 hours Charging Time With KSC 44 3 0 hours With micro USB 3 6 hours Note Talk r...

Page 4: ...d for 2 seconds to activate Super Lock P function Other functions can be assigned from the function list refer to PF Key Assignment Programmable Function Key 2 Hold this key for 2 seconds to stop start monitoring QT DQT Another function can be assigned from the function list refer to PF Key Assignment LED Indicator Indicate various status functions of the radio RED Transmitting GREEN Receiving a c...

Page 5: ...Key 2 Up Down to scroll the channels 3 Wait for 2 sec until beep tones sound the channel is set when the beep tones sound Indications 1 Channel Number is announced 2 Yellow LED blinks a number of times for the current channel BASIC Operations 1 Press PWR key Indications 1 Light blue LED flashes the number of times for battery levels LED Indicator Battery Level Blinks 3 Times High Blinks 2 Times Me...

Page 6: ... 4 sec to activate Super Lock P Indications 1 Single beep sounds Operations Deactivate 1 Turn the radio OFF hold the PF2 key and turn the radio ON Once Yellow LED lights release the PF2 key The ONLY operations allowed in Super Lock P mode are PTT Squelch Off Monitor Volume Up Down and Power On Off BASIC Operations ON 1 Hold PF2 key for 1 sec to turn on Monitor Indications 1 Single beep sounds Oper...

Page 7: ...2 sec to confirm the function chosen to be assigned to PF2 Hold 3 Hold the PTT for 3 sec Radio will store the current configuration and confirmation tone sounds and radio is reset and back to normal operation 4 To exit without save hold PWR key Power off tone sounds and radio is off without key function changes Table Functions PF1 Press PF1 Hold PF2 Hold 0 None 1 Low Transmit Power 2 Monitor 3 RX ...

Page 8: ...nounced when selected Press PTT to confirm the setup mode 6 In the QT DQT setup mode select QT DQT from the QT DQT table and table number will be announced 7 Press PTT to confirm the table number Radio will go back to Channel select mode 8 Repeat the step 1 to 7 to setup another channel s frequency QT DQT 9 To save exit hold PF2 PTT for 3 sec a confirmation tone sounds and radio is reset and back ...

Page 9: ...nfigure the VOX per channel status 3 In the selected channel press PF2 to control VOX ON OFF of the channel 4 To exit and save hold PTT for 3 sec confirmation tone sounds and radio is reset and back to normal operation 5 To exit without save press hold PWR Power off tone sounds and radio is off Self Programming Timer is 20 seconds First turn Off the radio then operate keys to enter each mode Selec...

Page 10: ...ne is successful the Slave radios will beep once and go back to normal operation mode 5 If clone is unsuccessful the Slave radios will beep 3 times as an error indicator and stay in clone mode 6 The Master radio will beep once after cloning transmission is completed and stay in clone mode To exit hold PWR Power off tone sounds and radio is off During cloning the Master s red LED is on during trans...

Page 11: ...d radio is off Self Programming Timer is 20 seconds First turn Off the radio then operate keys to enter each mode SELF PROGRAMMING First turn Off the radio then operate keys to enter each mode Mode Entry 1 Hold PWR PTT UP DOWN to enter the mode Indications 1 Yellow LED lights Operations 1 Release all keys within 2 sec 2 The radio will reset all default frequencies VOX function VOX gain level Key A...

Page 12: ...11 461 0875 36 466 0875 61 467 1875 86 468 4625 12 461 1125 37 466 1125 62 467 4625 87 468 5125 13 461 1375 38 466 1375 63 467 4875 88 468 5625 14 461 1625 39 466 1625 64 467 5125 89 468 6125 15 461 1875 40 466 1875 65 451 1875 90 468 6625 16 461 2125 41 466 2125 66 451 2375 91 456 3375 17 461 2375 42 466 2375 67 451 2875 92 456 4375 18 461 2625 43 466 2625 68 451 3375 93 456 5375 19 461 2875 44 4...

Page 13: ...4 D271I 153 D624I 9 D054N 38 D263N 67 D606N 96 D072I 125 D306I 154 D627I 10 D065N 39 D265N 68 D612N 97 D073I 126 D311I 155 D631I 11 D071N 40 D271N 69 D624N 98 D074I 127 D315I 156 D632I 12 D072N 41 D306N 70 D627N 99 D114I 128 D331I 157 D654I 13 D073N 42 D311N 71 D631N 100 D115I 129 D343I 158 D662I 14 D074N 43 D315N 72 D632N 101 D116I 130 D346I 159 D664I 15 D114N 44 D331N 73 D654N 102 D125I 131 D351...

Page 14: ......