(No.RA075<Rev.001>)1-55
5. Sensitivity 1
<PC>
1) Adj item: [Sensitivity 1]
2) SSG output: -100dBm (2.24
μ
V)
(MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[Low1], [Low4], [Center3],
[High1], [High4]
SSG
Distortion
meter
Oscilloscope
[
←
], [
→
]
<PC>
[Automatic Adjustment]
1) Press the "Start" key in the Auto
Tuning, and the RSSI value is
updated.
2) Continue to above process for
each adjustment point.
3) Press [Apply All] key after all
adjustments are finished and
check the newest RSSI.
<PC> <Panel>
[Manual Adjustment]
1) The PC window or the sub LCD
display shows the RSSI level.
2) Change the adjustment value to
get maximum RSSI level.
3) Press [Apply All] key for
<PC>
, or
press [ ] key for
<Panel>
to
store the adjustment value.
<Panel>
1) Adj item: [An SENS1]
2) SSG output: *Same as above
3) Adj points: *Same as above
[
], [
]
6.RSSI
Reference
<PC>
1) Adj item: [RSSI Reference
(Analog Narrow)]
2) SSG output: 12dB SINAD level
-3dB (MOD: 1kHz/±1.5kHz)
3) Adj points: 5 points
[Low1], [Low4], [Center3],
[High1], [High4]
SSG
Distortion
meter
Oscilloscope
After input signal from SSG;
Press [Apply] key for
<PC>
to store
the adjustment value at each
adjustment point.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [An RRSSI]
2) SSG output: *Same as above
3) Adj points: *Same as above
7.Open
Squelch
[Analog Wide]
<PC>
1) Adj item: [Open Squelch (Analog
Wide)]
2) SSG output: 12dB SINAD level at
Analog Wide -3dB
(MOD: 1kHz/±3kHz)
3) Adj points: 5 points
[Low1], [Low4], [Center3],
[High1], [High4]
SSG
Distortion
meter
Oscilloscope
After input signal from SSG;
Press [Apply] key for
<PC>
to store
the adjustment value at each
adjustment point.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [Aw SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
[NXDN
Narrow]
<PC>
1) Adj item: [Open Squelch (NXDN
Narrow)]
2) SSG output: 12dB SINAD level at
Analog Wide -1dB
(MOD: 400Hz/±2.5kHz)
3) Adj points: 5 points
[Low1], [Low4], [Center3],
[High1], [High4]
SSG
Distortion
meter
Oscilloscope
After input signal from SSG;
Press [Apply] key for
<PC>
to store
the adjustment value at each
adjustment point.
Or press [ ] key for
<Panel>
to
store the adjustment value at each
adjustment point.
<Panel>
1) Adj item: [Nn SQL]
2) SSG output: *Same as above
3) Adj points: *Same as above
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method