1-44 (No.RA075<Rev.001>)
4.4
BER (Bit Error Rate) Measurement
(1) The Panel Test Mode is used to measure the BER (Refer
"4.2.1 Test mode operation features").
(2) Select "7" (NXDN Mode) for test signaling (Refer to "4.2.3
Frequency and Signaling" (2) Test signaling).
Note:
"7" (NXDN Mode) can be selected only by PC test mode.
(3) The bandwidth is fixed to Narrow.
(4) Select a test frequency ("4.2.3 Frequency and Signaling"
(1) Test frequency).
(5) Measure the BER (Bit Error Rate) using the digital radio
tester.
Enter a standard input signal into the transceiver as a
FSW+PN9 for NXDN.
(6) Adjust the input signal level to achieve the standard bit
error rate (BER).
(For example, if the BER is 0.86%, the display shows
"0.86".)
4.5
Adjustment points
4.6
Test Equipment Required for Alignment
*The test equipment which is not used for adjustment is contained in this table.
MAIN UNIT (XC1-286)
Component side
RTC
Test Equipment
Major Specifications
1. Standard Signal
Generator (SSG)
Frequency Range
Modulation
Output
10 to 100MHz
Frequency modulation and external modulation
-127dBm/0.1uV to greater than -20dBm/22.4mV
When performing the Frequency adjustment, the following accuracy is necessary.
• 0.003ppm
Use a standard oscillator for adjustments, if necessary.
2. Power Meter
Input Impedance
Operation Frequency
Measurement Capability
50ohm
10 to 100MHz
Vicinity of 200W
3. Deviation Meter
Frequency Range
10 to 100MHz
4. Digital Volt Meter
(DVM)
Measuring Range
Input Impedance
10mV to 20V DC
High input impedance for minimum circuit loading
5. Oscilloscope
DC through 30MHz
6. Frequency Counter
Frequency Range
Frequency Stability
10Hz to 1000MHz
0.2ppm or less
To measure the oscillating frequency of the internal clock 32766.00Hz~32770.00Hz for
RTC Correction Resolution 0.01Hz is better for accuracy adjustment.
7. Ammeter
30A or more
8. AF Volt Meter (AF VM)
Frequency Range
Voltage Range
50Hz to 10kHz
1mV to 10V
9. Audio Generator (AG)
Frequency Range
Output
50Hz to 5kHz or more
0 to 1V
10. Distortion Meter
Capability
Input Level
3% or less at 1kHz
50mV to 10Vrms
11. Spectrum Analyzer
Measuring Range
DC to 1GHz or more
12. 4ohm Dummy Load
Approx. 4ohm, 30W
13. Regulated Power Supply
13.4V, approx. 30A (adjustable from 9V to 17V)
Useful if ammeter equipped