(No.RA015<Rev.001>)1-63
9.
Tight
Squelch
[Analog
Wide]
1) Adj item:
[Aw SQLT]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
+6dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Tight Squelch (Ana-
log Wide)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow
+6dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Narrow]
1) Adj item:
[An SQLT]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
+6dB
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[Tight Squelch (Ana-
log Narrow)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow
+6dB
(MOD: 1kHz/
±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifi-
cations
/Remarks
Panel tuning mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method