(No.RA070<Rev.001>)1-45
7. DMR High
Deviation
<PC>
1) Adj item: [DMR High Deviation
(DMR Narrow)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 10 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L], [8RX/TA C],
[8RX/TA H], [9TX L], [9TX H],
[9RX/TA L], [9RX/TA H]
4) Press [Transmit] button.
[+], [-]
Write fixed value "496" for each
adjustment point. Transmit at
each adjustment point and check
that the Analog deviation is within
the Specifications.
Press [Apply] button for
<PC>
, or
[ ] button for
<Panel>
to store
the adjustment value.
2695~2803Hz
<Panel>
1) Adj item: [D DDEV]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
8. QT
Deviation
[Analog Wide
5k]
<PC>
1) Adj item: [QT Deviation (Analog
Wide 5k)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 6 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L], [8RX/TA C],
[8RX/TA H]
4) Press [Transmit] button.
Deviation
meter
Oscilloscope
[+], [-]
Write fixed value "518" for each
adjustment point. Transmit at
each adjustment point and check
that the Analog deviation is within
the Specifications.
Press [Apply] button for
<PC>
, or
[ ] button for
<Panel>
to store
the adjustment value.
0.75kHz
±0.05kHz
<Panel>
1) Adj item: [Aw QT]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
[Analog Wide
4k]
<PC>
1) Adj item: [QT Deviation (Analog
Wide 4k)]
2) Deviation meter
LPF: 3kHz/ HPF: OFF
3) Adj points: 6 points
[8TX L], [8TX C], [8TX H],
[8RX/TA L],
[8RX/TA C], [8RX/TA H]
4) Press [Transmit] button.
Deviation
meter
Oscilloscope
[+], [-]
Write fixed value "519" for each
adjustment point. Transmit at
each adjustment point and check
that the Analog deviation is within
the Specifications.
Press [Apply] button for
<PC>
, or
[ ] button for
<Panel>
to store
the adjustment value.
0.60kHz
±0.05kHz
<Panel>
1) Adj item: [As QT]
2) Deviation meter
*Same as above
3) Adj points: *Same as above
4) PTT : ON
[
], [
]
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
<PC>: PC tuning mode
<Panel>: Panel tuning mode
Unit Parts
Method