![Kenwood NX-3200 Service Manual Download Page 41](http://html.mh-extra.com/html/kenwood/nx-3200/nx-3200_service-manual_193350041.webp)
(No.RA058<Rev.001>)1-41
*PC tuning
Connect the wires to the PCB in the connector case of
interface cable.
For output the wires out of the connector case, need to
process the connector case.
4.6
Radio check Section
Connector case
KPG-36U/36X
Remove the screw
PCB layout
Shield
Audio generator
100 10V
100 10V
10 10V
+
+
+
8
AF Voltmeter
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel test mode
PC test mode
Test-
equipment
Unit Terminal Unit Parts
Method
1.
Frequency
check
1)CH-Sig: 1-1
PTT: ON
1)Test Channel
Channel: 1
Test Signaling Type: Analog
Signaling: 1
PTT: Press [Transmit] button.
f. counter
Panel ANT
Check an
internal
temperature
of radio from
20
°
C to
33
°
C.
±0.5ppm
±77.5Hz@
155.1MHz
2.
High
power
check
(Battery
voltage:
7.5V)
1)CH-Sig: 1-1
PTT: ON
1)Test Channel
Channel: 1
Test Signaling Type: Analog
Signaling: 1
PTT: Press [Transmit] button.
Power meter
Ammeter
Panel ANT
Check
4.0~6.0W
2.0A or less
2)CH-Sig: 2-1
PTT: ON
2)Test Channel
Channel: 2
Test Signaling Type: Analog
Signaling: 1
PTT: Press [Transmit] button.
3)CH-Sig: 3-1
PTT: ON
3)Test Channel
Channel: 3
Test Signaling Type: Analog
Signaling: 1
PTT: Press [Transmit] button.