![Kenwood NX-3200 Service Manual Download Page 170](http://html.mh-extra.com/html/kenwood/nx-3200/nx-3200_service-manual_193350170.webp)
1-170 (No.RA058<Rev.001>)
5.7
Replacing TX-RX Unit
TX-RX unit information
Method of confirming “Original TX-RX unit” and “Service
TX-RX unit”
Supplied Accessories of “Service TX-RX unit”
“Service TX-RX unit” Data
The following data is written on the service unit:
After Changing the PCB
(1) After changing the printed circuit board, write the up-to-
date Firmware following the instructions in the “2.2
REALIGNMENT - 2.2.6 Firmware Programming Mode”.
• Write the Firmware in accordance to the Market. If you
write different Market Firmware, there are times
communication with the FPU is not possible.
(2) Using the KPG-D3/D3N, select your desired item (Model
Name) from the Radio Configuration> Product
Information menu, then use Read/ Write > Write
Configuration to the Transceiver to write the FPU data
(PC Programming mode). When writing to the
transceiver, a Warning Message, corresponding to the
item selected, appears. Click [OK] to continue writing the
data.
(3) Tools > Test/Tuning, then adjust the various adjustment
data (PC Test Mode) as described in the "SECTION 4
ADJUSTMENT".
(4) Attach the new labels corresponding to the new printed
circuit board. (Refer to the images below for label
placement.)
(5) If necessary, write the FPU data used by the customer
with the KPG-D3/D3N.
Note:
• When using the ESN Validation function of NXDN
Trunking, the NXDN ESN number changes when the
circuit board is changed (the number is written on the
circuit board); the NXDN Trunking System cannot be
accessed. Use the KPG-110SM on the NXDN Trunking
System side to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the KENWOOD
ESN changes, as does the Transceiver Information
display of the KPG-D3/D3N, but this does not have any
effect on the operation of the transceiver.
• If changing to the original ESN, please contact our service
center.
• KPG-D3N can't be used for E, E2, E3 types.
Model Name
Original TX-RX unit
Number
For Service TX-RX
unit Number
NX-3200
(K,K2,K3)
XC1-179K-00
XCA-031K-00
NX-3200
(E,E2,E3)
XC1-179K-00
XCA-031E-01
NX-3300
(K,K2,K3)
XC1-181K-00
XCA-032K-00
NX-3300
(E,E2,E3)
XC1-181K-00
XCA-032E-01
Item (Including Parts Number)
Quantity
TX-RX Unit (XC1-179, XC1-181)
1
KENWOOD ESN/ NXDN ESN/ Product
Number/ MPT ESN Label
1
The following marking seals are affixed on
the shield cover of the service TX-RX unit
(XCA-031K-00/XCA-031E-01/XCA-032K-00/
XCA-032E-01).
Model Name
Marking seal
NX-3200
(K,K2,K3)
XCA-031K-00
NX-3200
(E,E2,E3)
XCA-031E-01
NX-3300
(K,K2,K3)
XCA-032K-00
NX-3300
(E,E2,E3)
XCA-032E-01
Data Type
Description
KENWOOD ESN
Model name: [XCA-031/XCA-032]
NX-3200S (K, E)/NX-3300S (K, E)
Type:K, K2, K3, E, E2, E3
The same number as the KENWOOD
ESN label is written.
NXDN ESN/ MPT ESN/
Product number
The same number as the NXDN ESN/
MPT ESN/ Pruduct Number label is
written.