NX-210(G)
40
• Analog mode signaling
No.
RX
TX
1
None
None
2
None
100Hz Square Wave
3
LTR Data:
AREA=0, GOTO=12
HOME=12
ID=47, FREE=25
LTR Data:
AREA=0, GOTO=12
HOME=12
ID=47, FREE=25
4
QT: 67.0Hz
QT: 67.0Hz
5
QT: 151.4Hz
QT: 151.4Hz
6
QT: 210.7Hz
QT: 210.7Hz
7
QT: 254.1Hz
QT: 254.1Hz
8
DQT: D023N
DQT: D023N
9
DQT: D754I
DQT: D754I
10
DTMF: 159D
DTMF: 159D
11
None
DTMF Code 9
12
2-tone:
A: 304.7Hz
B: 3106.0Hz
2-tone:
A: 304.7Hz
B: 3106.0Hz
13
Single Tone: 979.9Hz
Single Tone: 979.9Hz
14
None
Single Tone: 1000Hz
15
None
MSK
16
MSK
MSK
• NXDN mode signaling
No.
RX
TX
1
RAN1
RAN1
2
None
PN9
3
RAN1
Maximum deviation pattern
7
None
FSW+PN9
9
Tone Pattern (1031Hz) Tone Pattern (1031Hz)
RAN: Radio Access Number
PN9: Pseudo-Random Pattern (for production only)
No.7,9 item: PC test mode only
Panel Tuning Mode
■
Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the
unit to a suitable power supply.
Whenever the transmitter is turned, the unit must be con-
nected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with a
8
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
■
Transceiver tuning (To enter tuning mode)
To enter tuning mode, press the [ ] key while the trans-
ceiver is in test mode. Use the [ ] key to write tuning data
through tuning modes, and the [
]/[
] key to adjust tuning
requirements (1 to 4096 appears on the LCD).
Use the [
] key to select the adjustment item through
tuning modes. Use the [ ] key to adjust 5 reference level ad-
justments, and use the [Side2] key to switch between Wide/
Narrow/Very narrow.
• LCD display in panel tuning mode
An CNTR 256
2.6
CV voltage, AD value, etc
Sub LCD display
Main LCD display
Adjustment value
(1~4096)
Proper value guide
(When the frequency
adjustment is necessary,
or is displayed.)
Adjustment item
Adjustment
point
L,L’,C,H’,H
An: Analog narrow mode
Aw: Analog wide mode
Nn: NXDN narrow mode
Nv: NXDN very narrow mode
■
Key operation
Key
Function
Push
Hold (1 second)
[Selector]
-
[
]
Adjustment value up
Continuation up
[
]
Adjustment value down
Continuation down
[Side1]
Auto adjustment start
-
[Side2]
Wide/Narrow/Very narrow
-
[ ]
Shift to panel test mode
-
[ ]
To enter 5 reference level
adjustments
-
[ ]
Writes the adjustment
value
-
[
]
Go to next adjustment
item
Back to last adjustment
item
[Orange]
-
[PTT]
Transmit
[0] to [9]
and
[#], [ ]
-
■
5 reference level adjustments frequency
Tuning point
RX (MHz)
TX (MHz)
Low
136.05000
136.10000
Low’
145.55000
145.60000
Center
155.05000
155.10000
High’
164.55000
164.60000
High
173.95000
173.90000
ADJUSTMENT