![Kenwood KRC-225 Service Manual Download Page 3](http://html.mh-extra.com/html/kenwood/krc-225/krc-225_service-manual_1955491003.webp)
KRC-225/235/265/265S
3
COMPONENT DESCRIPTION
Ref.No.
Component Name
Application/Function
Operation/Condition/Compatibility
IC1
LC72366-9592
System MI-COM.
System control
IC2
TDA7461ND
E-VOL. & N.C. MPX
Controls sound volume. Selects each source.
IC3
HD74HC27FP
Mute logic
3-input NOR gate x 3
IC4
TDA7384A or
Power IC
Amplifies power so that the speaker can drive audio signal.
TDA7386
IC5
LA3161
Equalizer amplifier
Equalizer amplifier for cassette tape sound
2SC2412K or
BACK-UP detection
While BACK-UP is added, a base becomes Hi, and Q50 is
Q50
2SD601A
(Momentary power down
turned on.
detection) SW
Q51
2SB1443
While BACK-UP is added, AVR o5V.
Q52
2SC2412K or
BACK-UP 5V AVR
Q51 and Q52 is inverted Darlington connection.
2SD601A
Q53
DTA114YK or UN2114
P.ON 5V SW
While a base becomes Lo, Q53 is turned on.
or KRA107S
Q54
DTC144EK or UN2213
While Q54's base becomes Hi, Q55 is turned on.
or KRC104S
COM+B SW
Q55
DTA124EK or UN2112
Works during POWER ON mode.
or KRA103S
2SA2057 or 2SB1548
Q56
(P) or 2SB1565(E,F)
While Q57's base becomes Hi, Q56 is turned on.
or 2SB1655(E,F)
COM+B AVR
Q57
2SC2412K or
Q56 and Q57 is inverted Darlington connection.
2SD601A
Q58
DTC144EK or UN2213
While Q58's base becomes Hi, Q59 is turned on.
or KRC104S
IllumiB SW
Q59
DTA124EK or UN2112
Works during POWER ON mode with a panel attached
or KRA103S
to the set.
2SA2057 or 2SB1548
Q60
(P) or 2SB1565(E,F)
While Q61's base becomes Hi, Q60 is turned on.
or 2SB1655(E,F)
IllumiB driver
Q61
2SC2412K or
Q60 and Q61 is inverted Darlington connection.
2SD601A
DTC124EK or UN2212
When BACK-UP detection SW or CHANGER RESET SW or
Q150
or KRC103S
Electric volume mute SW
MI-COM.'s mute works, a base becomes Hi, and Q150
is turned on.
Q151
DTC114YK or UN2214
SVR discharge SW
When POWER IC RESET is activated, a base becomes Hi,
or KRC107S
Q151 is turned on.
DTA124EK or UN2112
When BACK-UP detection SW or CHANGER RESET SW or
Q153
or KRA103S
Pre-out mute driver
MI-COM.'s mute works, a base becomes Lo, and Q153
is turned on.
Q200
DTC124EK or UN2212
Q201 is turned on when Q200's base becomes Hi.
or KRC103S
FM +B SW
Q201
2SB1277(Q,R)
Works during FM reception mode.
Q202
DTC124EK or UN2212
Q203 is turned on when Q202's base becomes Hi.
or KRC103S
AM +B SW
Q203
2SB1277(Q,R)
Works during AM reception mode.
¶
SWITCH UNIT(X16-1490-XX)
Ref.No.
Component Name
Application/Function
Operation/Condition/Compatibility
IC1
LC75853NE
LCD driver with key-matrix
Q1
DTA114EK or UN2111
Key-matrix permission SW Ready on key-matrix
or KRA102S
¶
SYNTHESIZER UNIT(X14-6850-XX)