5
KMD-44
COMPONENTS DESCRIPTION
Ref. No.
Component name
Application/Function
Operation/Condition/Compatibility
IC1
LC75808W
LCD driver with key-matrix
IC2
RS-171
Remote control light sensor
Q1
DTA114EK or UN2111
Key-matrix permission SW
Ready on key-matrix, ON when the base goes "Lo".
Q2
2SD2114K
Illumination SW(Red)
ON when the base goes "Hi".
Q3
2SD2114K
Illumination SW(Green)
On when the base goes "Hi".
Q4
2SC2412K or 2SD601A
LCD AVR
Ref. No.
Component name
Application/Function
Operation/Condition/Compatibility
IC1
UPD784216GF531
System MI-COM.
IC2
TDA7407D
E-VOL. & N.C. MPX
IC3
M5237ML
AVR IC
AVR IC is combined with Q5, and it works as the error
detection, the driver.
IC4
TDA7386
Power IC
IC6
LM2595S-ADJ
MD SERVO AVR
A DC/DC Converter wiht the ON/OFF function.
IC7
S-80830ANNP
Reset IC
"L" : detection voltage below 3.0V
IC8
HD74HC27FP
Mute logic
3 input NOR gate x3
IC10
TDA7479D
RDS decoder
Q1
2SC4081 or 2SD1819A
BU 5V AVR
Inverted darlington connection
Q2
2SB1548(P)or 2SB1655(E, F)
On during BU applied.
Q3
DTA124EUA or UN5112
Audio 8V AVR ON/OFF control
Q4
DTC144EK or UN2213
Audio 8V AVR ON/OFF SW
Q3 is turned ON when Q4's base goes "Hi".
or KRC104S
Q5
2SB1548(P)or 2SB1655(E, F) Audio 8V AVR
Output voltage 8.3V
Q7
DTC144EUA or UN5213
Q8
DTA124EUA or UN5112
Illumination AVR
AVR output is ON when Q7's base goes "Hi".
Q9
2SD1760
Q10
2SA1037K
SW 5V
ON when the base goes "Lo".
Q13
2SB1277(Q, R)
Q16
DTC114YK or UN2214
P-CON SW
Q13 is turned ON when Q16's base goes "Hi".
or KRC107S
Q14
2SA1037K
Protect Q13 by turning ON when P-CON output is grounded.
Q15
DTA124EK or UN2112
P-CON protection
Prevents Q14 turning ON during start-up after power ON.
or KRA103S
Q17
2SC2412K or 2SD601A
BU detection
ON when the base goes "Hi" during BU applied.
(Momentary power down detection)
Q18
2SC2412K or 2SD601A
ACC detection
ON when the base goes "Hi"during ACC applied.
Q19
DTA124EK or UN2112
Mute driver for Audio mute SW
ON when the base goes "Lo".
or KRA103S
Q20
DTC144EK or UN2213
E-VOL. mute SW
E-VOL. is muted when the base goes "Hi".
or KRC104S
Q21, 22 DTC143TK or UN2216
Audio mute SW
Audio pre-outs are muted when the base goes "Hi".
Q23
DTC114YK or UN2214
SVR SW
POWER IC RESET is activated when the base goes "Hi".
Q24
DTA114YUAor UN5114
Panel detection SW
ON when the base goes "Lo" during the panel closed.
Q25
DTC124EK or UN2212
or KRC103S
FM+B SW
Q26 is turned ON when Q25's base goes "Hi".
Q26
2SB1277(Q,R)
ON during FM reception
Q27
DTC124EK or UN2212
Q28 is turned ON when Q27's base goes "Hi".
or KRC103S
AM+B SW
Q28
2SB1277(Q,R)
ON during AM reception
Q29
2SC4081 or 2SD1819A
Composite signal output buffer
Q30
2SC4081 or 2SD1819A
Noise buffer
Q33
DTC144EK or UN2213
RESET SW
System RESET is activated when the panel reset SW
or KRC104S
is pushed
Q34
2SC4081 or 2SD1819A
DSI driver
ON when the base goes "Hi".
●
SWITCH UNIT (X13-9700-11)
●