17
KDC-W8534/W8534Y
KDC-X790
TEST MODE
●
OPEL communication items
During the test mode, OPEL communication line outputs the
following (At every 500msec, the output condition of the com-
munication line will be switched.)
●
G sensor display items
When source is STANDBY, by short-pressing [ATT] key, the
display is switched to analogy meter display, in which vertical
G and horizontal G are displayed.
●
Special display when all lights are on
When all lights are on with the STANDBY source, the follow-
ing displays are made when the keys shown below are pressed.
[1] key
Version display
(Display) C0507WE__SYS1. 23
(Display) STYPE : x__PAN1.11
(Display) PTYPE : x__MEM3.21
∗
STYPE indicates system
µ
-com destination, and PTYPE
indicates panel
µ
-com destination, and show real-time
condition of the destination terminal (“x” is displayed in
hexadecimals.)
[2] key
Serial number display (8 digits)
(Display) SNo_XXXXXXXX
[3] key
Key pressed briefly : Power ON time is displayed.
During Power On time display, by pressing for at least 2
seconds, the Power ON time is cleared.
(Display) PonTim_0Hxx_ (00~50 is displayed for “xx”.
When less than 1 hour, displayed
by increments of 10 minutes.)
xxxxx
(00001~10922 is displayed for
“xxxxxx”.) MAX 10922 (times)
[4] key
Key pressed briefly : CD operation time is displayed.
During CD operation time display, by pressing for at least
2 seconds, CD operation time is cleared.
(Display) CDTim_0Hxx_ (00~50 is displayed for “xx”.
When less than 1 hour, displayed
by increments of 10 minutes.)
xxxxx
(00001~10922 is displayed for
“xxxxxx”.) MAX 10922 (times)
[5] key
Key pressed briefly : CD EJECT number is displayed.
During CD EJECT number display, by pressing for at
least 2 seconds, CD EJECT number display is cleared.
(Display) EjeCnt_xxxxx
MAX 65535 (times)
[6] key
Key pressed briefly : PANEL Open/close number is
displayed. (*1)
During PANEL Open/close number display, by pressing
for at least 2 seconds, PANEL Open/close numbers is
cleared.
(Display) PnCnt_xxxxx
MAX 65535 (times)
[FM]
ROM correction version display
key
(Display) SYS_ROM_R123
(Display) PAN_ROM_R123
When E2PROM is not installed : ROM_ERR_
When un-written : ROM_R – – –
When data is incompatible : ROM_R
∗ ∗ ∗
[
]
AUDIO data default value setting
key
(Display) AUDIO_INIT
[
]
Key pressed briefly : Forced Power OFF data displayed.
key
While the forced power OFF data is displayed, press and
hold for 2 seconds to clear the data.
(Display) POFF_ - - - (No Forced Power OFF)
SEC
(Forced Power OFF because of
missing Security Code)
PNL
(Forced Power OFF because of
system
µ
-com panel communication
error)
[
]
Key pressed briefly : CD information display mode ON/OFF
key
While in CD information display mode, press and hold for
2 seconds to clear all CD information.
∗
Please refer to the table below.
(*1) : 1 count is made when the panel opens to full or when a disc is
loaded.
CE
DATA
CLK
500msec
500msec
500msec