4
KDC-MP5033U/MP532U
KDC-W534UA/UAY/UG/UGY/W5534U/UY
COMPONENTS DESCRIPTION
●
ELECTRIC UNIT (X34-412x-xx)
Ref. No.
Application / Function
Operation / Condition / Compatibility
IC1
Power Supply IC
DC5V x 1, 7.9V x 1, 8.1V x 2, 10.2V x 1, P-CON, P-ANT output.
IC2
Power Supply IC
DC5V for CD mechanism unit and USB.
IC3
Hi-side SW
USB5V on when the pin 1 goes “Hi”.
IC10
E-VOL & Tuner
E-VOL, Tuner, Stereo decoder.
IC101
System
µ
-COM
Controls system.
IC102
Reset IC
“Lo” when detection voltage is below 3.6V.
IC103
E2PROM
Saves and loads for tuner adjustment data.
IC201
Power IC
Amplifies signal.
IC400
RDS Decoder
Decodes RDS.
Q1
SERVO+B AVR
Darlington connection with Q2. (Current buffer)
Q2
SERVO+B AVR
Outputs 7.5V.
Q3
14V SW
“ON” when the base goes “Hi”.
Q4
VFD+B & LED AVR
Darlington connection with Q5. (Current buffer)
Q5
VFD+B & LED AVR
Outputs 11V.
Q6
VFD+B & LED SW
“ON” when the base goes “Hi”.
Q7
Non Back Up 5V SW
“ON” when the base goes “Lo”.
Q8
Control SW for IC1
Q9
Serge Protect for IC2
Darlington connection with Q5. (Current buffer)
Q10
Serge Protect for IC2
Outputs 15V when back up voltage is over 16V.
Q11
Control SW for IC2
IC2 turns on when the base goes “Lo”.
Q12
FL FIL Voltage SW
FL FIL voltage ON/OFF SW.
Q13
Control SW for Q12
Q12 turn on when the base goes “Hi”.
Q51
Serge DET
“ON” when the base goes “Hi”.
Q52
BU DET
“ON” when the base goes “Hi” during BU is applied.
Q53
ILLUMI SW
“ON” when the base goes “Hi”.
Q54
ACC DET
“ON” when the base goes “Hi” during ACC is applied.
Q101
PANEL5V SW
“ON” when the base goes “Lo”.
Q102
Control SW for D111
D111 is ON when the base goes “Hi”.
Q103,104
Mute Control
“ON” when the base goes “Hi”.
Q105
Mute Driver for Preout
“ON” when the base goes “Lo”.
Q201,202
DC Offset DET SW
“ON” when the base goes “Lo”. (At that time, IC201’s SP-OUT DC is
separated)
Q203
DC Offset DET
“ON” when the base goes “Hi”. (At that time, Q201 and Q202’s outputs
are separated)
Q204
SVR Discharge
IC201’s pin 10 discharges when the base goes “Hi”.
Q251
Mute SW for Lch Preout
Pre-output is muted when the base goes “Hi”.
Q252
Mute SW for Rch Preout
Pre-output is muted when the base goes “Hi”.
Q400
Buffer
IC10 QUAL output buffer.
Q501
AM RF Amplifier
Adjusts for gain.
Q502
FM RF Amplifier
Amplifies RF.
Q503,504
AFS Control
Controls AFS time.