KDC-MP5032
12
TEST MODE
[
]
AUDIO data initialization
key
(Display) AUD_INIT
[
]
Key pressed briefly: Forced Power OFF data displayed.
key
While the forced power OFF data is displayed, press and
hold for at least 2 seconds to clear the data.
(Display) POFF_ - - - (No Forced Power OFF)
PNL
(Forced Power OFF because of
system
µ
-com and panel communi-
cation error)
[
]
Key pressed briefly: CD information display mode ON/OFF
key
While in CD information display mode, press and hold for
at least 2 seconds to clear all CD information
∗
Please refer to the next table.
(*1) : 1 count is made when the panel opens to full or when a disc is
loaded.
CD information display mode
I2C communication condition display
(Display) I2C_OK__
NG
CD mechanism error log display
[switched by [
] / [
] keys]
(Display) MCERR1 : xx
↔
MCERR2 : xx
↔
MCERR3 : xx
↔
MCERR1 : xx
↔
(“--” or the error code is displayed for “xx”.)
[AM]
Displays CD loading error data.
key
[switched by [
] / [
] keys]
↓
(Display) LDERR1: xx
↔
LDERR2 : xx
↔
LDERR1: xx
↔
(number of times is displayed for “xx”)
MAX 99 (times)
Disk detection switch ON/OFF is monitored, and when the
loading operation is not completed within the specified
time length, or when E-99 mechanism error occurred,
record which SW signal had an error.
∗
Refer to the note at the end of [CD LOAD error detection].
Displays CD ejection error data.
[switched by [
] / [
] keys]
(Display) EJERR1 : xx
↔
EJERR2 : xx
↔
EJERR3 : xx
↔
EJERR4 : xx
↔
EJERR1 : xx
↔
(number of times is displayed for “xx”)
MAX 99 (times)
Disk detection SW ON/OFF is monitored, and when the
ejection operation is not completed within the specified
time length, or when E-99 mechanism error occurred,
record which SW signal had an error.
∗
Refer to [CD EJECT error detection]’ s note.
↑
Displays CD time code count error data (missing count).
[FM]
[switched by [
] / [
] keys]
key
(Display) CNT_LOSE
↔
CDDA__ : xx
↔
CDROM_ : xx
↔
CNT_LOSE
↔
(number of times is displayed
for “xx”)
MAX 99 (times)
Monitor time code continuity. Record the number of times
when discontinuity occurred as error data.
Record the data of compressed audio and CD-DA played
separately.
Displays CD time code count error data (count not updated).
[switched by [
] / [
] keys]
(Display) CNT_STAY
↔
CDDA__ : xx
↔
CDROM_ : xx
↔
CNT_STAY
↔
(number of times is displayed
for “xx”)
MAX 99 (times)
When the time code is not renewed for 2 or more seconds,
record the number of times occurred as error data
(skipped sound).
●
Initializing AUDIO-related value setting
During STANDBY sourcing, by pressing [
] key for less than
1 second, AUDIO setting values are returned to the default
values.