KDC-MP333V/MP333VS
12
CD ejection error log display (switched by [
] / [
] keys)
(Display) EJERR1: x x
↔
EJERR2: x x
↔
EJERR3: x x
↔
EJERR4: x x
↔
EJERR1: x x
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
CD time code error count data display (missing counts)
(switched by [
] / [
] keys)
(Display) CNT_LOSE
↔
CDDA_ _: xx
↔
CDROM_: xx
↔
CNT_LOSE
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
↓
CD time code error count data display (count not updated)
[FM]
(switched by [
] / [
] keys)
key
(Display) CNT_STAY
↔
CDDA_ _: xx
↔
CDROM_: xx
↔
CNT_STAY
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
●
Initializing AUDIO-related setting value
Press the [
] key in the STANDBY source and reset the AU-
DIO setting value to the test mode default value.
●
Other
• When started in Test Mode, duration of prohibiting LINE
MUTE shall be changed from 10 seconds to 1 second.
• When in Test Mode, when DC offset error detection is run,
the detection information is not written into the E2PROM.
●
Clearing CD mechanism information and service
information (E2PROM data clearing)
1. While pressing the [Q] key and [ATT] key, reset-start to start
CD mechanism and service information initialization.
(While “– – – –“ is being displayed, power can be ON for 30
minutes.)
[CD mechanism information]
• Displays I2C communication condition
• Displays CD mechanism error log
• Displays CD loading error data.
• Displays CD ejection error data
• Displays CD time code error count data (missing count)
• Displays CD time code error count data (count not updated)
[Service information]
• Displays power ON time is displayed
• Displays CD operation time
• Displays number of CD EJECT times
• Displays number of times panel was opened/closed
• Displays forced Power OFF data
2. After the initialization process is completed, the following is
displayed.
When successfully completed
: “CD_O”
When finished but unsuccessful : “CD_X”
∗
CD mechanism information clearing is no good.
3. This mode is cancelled by resetting. (The last screen will
not be retained.)
●
Clearing DC offset error detection data
(E2PROM data clearing)
1. Press and hold [3] and [6] keys and reset-start to go into
the DC offset error display mode.
(While “– – – –“ is being displayed, power can be ON for 30
minutes.)
2. While in STANDBY source, the current DC offset error con-
dition is displayed.
When detected
: “DC_ERR_ _”
When not detected : “DC_OK_ _ _”
3. While error condition is being displayed, press [AUTO] key
to clear the detection data. (Clear E2PROM)
4. DC offset error display mode is cancelled by resetting. (The
last screen will not be retained.)
●
FM/AM channel space switching
While power is OFF, press and hold [1] and [5] keys, and press
[SRC] key to power ON.
●
IC10 (X34-) Stereo adjustment (VCO adjustment)
While in test mode and all lights are lit (STANDBY), press and
hold [1] key and press [6] key for 3 seconds or longer.
“VCO ADJ” will be displayed for a second.
(Adjusted data will be written on E2PROM.)
TEST MODE