KDC-MP333V/MP333VS
11
●
Special displays while all lights are on
When all lights are on with STANDBY source, if the following
keys are pressed, the following messages are displayed.
[1] key
Version is displayed (forwarding)
(Display) TYPE : x_ _ _ (“x” is displayed in hexadecimals)
→
650M – 2.02 (“development ID” – “version”)
→
all lights on
→
∗
TYPE indicates
µ
-com destination, and shows real-time
condition of the destination terminal.
[3] key
Key pressed: Power ON time is displayed.
While Power ON time is displayed, press the key for more
than 2 seconds to clear the Power ON time.
(Display)
PON_0Hxx (00~50 is displayed for “xx”. When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[4] key
Key pressed: CD operation time is displayed.
While the CD operation time is displayed, press the key
for more than 2 seconds to clear CD operation time.
(Display)
CDT_0Hxx (00~50 is displayed for “xx”. When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[5] key
Key pressed: Number of CD EJECT time is displayed.
While the CD EJECT times is displayed, press the key for
more than 2 seconds to clear the number of CD EJECT
times.
(Display) EJCxxxxx
MAX 65535 (times)
[6] key
Key pressed: Number of times PANEL is opened/closed
is displayed.
While the PANEL open/close count is displayed, press the
key for more than 2 seconds to clear the PANEL open/
close count.
(Display) PC_xxxxx
MAX 65535 (times)
[FM]
ROM correction version is displayed
key
(Display) _ _ _RD123
ROM_ERR_
(When E2PROM is not installed)
_ _ _R – – – – (When not written in)
_ _ _R
∗ ∗ ∗
∗
(When data not matching)
[AM]
IC10 adjustment status
key
“E2P_OK”: Adjustment completed
“E2P_ER” : E2PROM values are still default (not determined)
“I2C_ER” : Cannot communication with IC10/E2PROM
∗
If “E2P_OK”, Pin 41 (TUN FANC OUT) should be
output as “H”.
[
]
AUDIO data initialization
key
(Display) AUD_INIT
[
]
Key pressed: Forced Power OFF data displayed.
key
While the forced power OFF data is displayed, press the
key for more than 2 seconds to clear the data.
(Display) POFF_ – – – (No Forced Power OFF)
PNL (Forced Power OFF because of
system
µ
-com and panel communication error)
[
]
Key pressed: CD information display mode ON/OFF
key
While in CD information display mode, press the key for
more than 2 seconds to clear all CD information.
∗
Please refer to the next table.
CD information display mode
I2C communication condition display
(Display) I2C_OK_ _
NG
[AM]
CD mechanism error log display
key
(switched by [
] / [
] keys)
↑
(Display) MCERR1: x x
↔
MCERR2: x x
↔
MCERR3: x x
↔
MCERR1: x x
↔
(“– –” or the error code is displayed for “xx”)
CD loading error log display (switched by [
] / [
] keys)
(Display) LDERR1: x x
↔
LDERR2: x x
↔
LDERR1: x x
↔
(Number of times is displayed for “xx”)
MAX 99 (times)
TEST MODE