![Kenwood KDC-BT838U - Radio / CD Service Manual Download Page 21](http://html.mh-extra.com/html/kenwood/kdc-bt838u-radio-cd/kdc-bt838u-radio-cd_service-manual_187172021.webp)
21
KDC-BT7539U/BT8041U
/BT8141UY/BT838U
2.
Press the [FNC] key brie
fl
y to make the multi-function
display and press the [ ] key briefly to enter the
MENU.
When “Security” is displayed, press [ ] key for 1 sec-
ond or longer to enter the security registration mode.
3.
Enter codes with the operation knob in the right side
or with the [FM] / [AM] and [
] / [
] keys.
CW rotation of the operation knob, [FM] key: number
up
CCW rotation of the operation knob, [AM] key: number
down
[
] key
: cursor to right
[
] key
: cursor to left
4.
After inputting the code, press [ ] key for 3 seconds
or longer which causes “RE-ENTER” to be displayed.
This is for “con
fi
rming” the code. Use the method in
the step 3 to re-enter the code.
5.
Then, press [ ] key for 3 seconds or longer, which
will display “APPROVED”. This completes the security
code registration
6.
Release the test mode. (Refer to “How to clear the test
mode”.)
∗
Note
: All clear cannot be used to clear the security
code.
•
How to clear the programmable security code
(Simple security models)
1. While “_ _ _ _” is being displayed, press [ ] key for 3
seconds or longer while pressing the [AUTO] or [TI] keys.
(This makes the “_ _ _ _” display disappear.)
2. Input “KCAR”, using the remote controller.
Press [5] key of the remote controller 2 times (Input for “K”)
and press [ ] key.
Press [2] key of the remote controller 3 times (Input for “C”)
and press [ ] key.
Press [2] key of the remote controller once (Input for “A”)
and press [ ]key.
Press [7] key of the remote controller 2 times (Input for “R”)
and press [ ] key.
3. The security is cleared and the unit enters STANDBY
mode.
4. If wrong codes are input, “_ _ _ _” will be displayed
again.
●
Purpose
Prevent customer’s vehicle speakers damages, burnouts,
and smoking.
Avoid the connected speakers to be burned out, dam-
aged, or to smoke when DC occurs between the audio
power amp. + and - outputs.
●
Processing after detection
• System status
• At the detection of DC error, error data is to be saved im-
mediately (E2PROM error log save area).
• Display the error message on the display. The system
shall maintain the current condition, including the opera-
tion. Shut down audio system power supply. Set Mute to
ON.
• Although switching between Power OFF and ON (ACC,
BU, and Key operation) is valid, switching from Off to ON
shall be error until the
μ
-com is reset.
∗
While power-on, even if the IC2VI DCErr output termi-
nal logic recovered to normal level value, the error con-
dition shall continue.
• Prohibit to save the backup/installer memory to E2PROM
(nonvolatile memory).
●
Controlling
μ
-com terminal
• Set Mute for all channels including for pre-out.
• Turn off power IC control system power supply. (Set
AMP-Standby function to valid)
• Set P-Con output to OFF (Logic by which external AMP
unit is turned off).
DC OFFSET ERROR
TEST MODE