ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
70
TK-790/
(
B
)
/H
(
B
)
5. BPF
1) CH-SIG : 2-1
Spectrum
TX-RX
CN101
TX-RX
L112
Adjust the coils in
Spectrum analyzer
analyzer
(A/3)
(A/3)
L111
the following order
Span : 50MHz
L110
: L112, L111, L110
Scale : 5dB div
Tracking
Rear
ANT
Tracking generator
generator
Output : –20dBm
6. MCF
1) CH-SIG : 1-1
Spectrum
TX-RX
CN103
TX-RX
L118
Adjust it to make gain maximum, and make the
• Wide
Spectrum analyzer
analyzer
(A/3)
(A/3)
L119
band flat as shown in the below.
Span : 25kHz
L122
Scale : 2dB div
Tracking
CN102
Center frequency : 44.850MHz generator
Tracking generator
Output : –20dBm
• Narrow
1) Up/down knob : Set the narrow
L117
“n_ _” appear on the LCD
L120
L123
7. Distortion
1) CH-SIG : 1-1 (Wide)
SSG
Rear
ANT
Check
3% or less
SSG output : –53dBm/501
µ
V
Distortion
EXT.SP
If the distortion value
AF output : 2V/4
Ω
meter
exceeds 3%, you must
AF VTVM
adjust L127 to obtain a
Oscilloscope
minimum distortion value.
4
Ω
dummy
load
8. RF power
1) CH-SIG : 1-1
Power meter Rear
ANT
Final
VR1
Maximum clockwise 115W or more
• High power
Select _POW_XXX
Ammeter
model
in tune mode
110W adj.
110W
±
5W, 25A or less
(High power)
PTT : ON
Panel
PF3 key Check
110W
±
5W
PF4 key
(Low power) 1) CH-SIG : 1-1
45W adj.
45W
±
1W
Select LPOW_XXX
in tune mode
PTT : ON
REF 4.0dBm
5dB/
MARKER
22.00MHz
–18.70dB
RBW
300kHz
VBW
100kHz
DL
–1.05dBm
SWP
50m
s
SPAN 50.0MHz
CENTER 148.0MHz (K)
136.0MHz (K2)
ATT 10dB
10dB
or more
–22MHz
+22MHz
–5
MHz
+5
MHz
10dB
or more
5dB
REF –20.0dBm
2dB/
MARKER
4.50kHz
–0.28dB
RBW
300Hz
VBW
300Hz
DL
–22.02dBm
SWP
1.3
s
SPAN 25.0kHz
CENTER 44.8500MHz
ATT 10dB
3dB or more
(
±
10kHz)
–4.5kHz +4.5kHz
–10kHz
+10kHz
1.5dB max.
REF –20.0dBm
2dB/
MARKER
3.00kHz
–0.42dB
RBW
300Hz
VBW
300Hz
DL
–22.02dBm
SWP
1.0
s
SPAN 20.0kHz
CENTER 44.8500MHz
ATT 10dB
3dB or more
(
±
7kHz)
–7kHz
–3kHz
+7kHz
+3kHz
1.5dB max.