Clearing DC error detection information (E2PROM data clearing)
Procedure
Note
While pressing and holding [3] key and [6] key, reset-start.
To enter DC error display mode.
While “– – – –” is displayed, power can be ON for 30 minutes. This mode is cancelled by resetting. (The last screen will not be retained.)
Procedure
Display
Description
While pressing
and holding [3]
key and [6] key,
reset-start.
D
C
E
R
R
When DC error is detected (when either one of capacitor leak is leaking, or an im-
proper connection or other error is detected)
D
C
O
K
When DC error is not detected (when none of capacitor leak, no improper connection
or other error is detected)
1
D
C
1
E
R
R
When improper connection or other DC errors are detected.
D
C
1
O
K
When improper connection or other DC errors are detected.
■
1
D
C
1
O
K
When detecting improper connection or other DC errors, clears detection data. (Clear
EEPROM)
2
D
C
2
4
Capacitor leak detection period display of the detected times of capacitor leaks. (0~4)
■
2
D
C
2
0
Capacitor leak detection period to clear the times of the detections. (Clear EEPROM)
This mode is cancelled by resetting. (The last screen will not be retained.)
■
FM/AM channel space switching
Procedure
Note
While Power OFF, pressing and holding [1] key and [5] key,
and press [SRC] key to Power ON
FM200kHz/AM10kHz
↔
FM50kHz/AM9kHz
FM50kHz/AM10kHz
↔
FM200kHz/AM10kHz
■
Security
• Forced Power ON mode
Procedure
Note
While pressing and holding [M.JOG] key and [4] key, reset-start.
While “– – – –” is displayed, power can be turned ON for only 30
minutes. After 30 minutes, can only be recovered by resetting.
• How to register the security code on the “Car Audio Passport” after replacement of the FRONT-END
with E2PROM
Procedure
Description
While pressing and holding [1] key and [3] key, reset-start
Enters the Test mode
Press [M.JOG] key brie
fl
y
Enter the Menu mode.
Press and hold [AUD] key for 1 second or longer
Enter the Security Registration mode.
[FM] / [AM] / [
] / [
] key
Input the code. FM: Number up / AM: Number down /
: Cursor to the left /
: Cursor to the right
Press and hold [AUD] key for 3 second or longer
“RE-ENTER” is displayed.
[FM] / [AM] / [
] / [
] key
Inputs the code again. FM: Number up / AM: Number down /
: Cursor to the left /
: Cursor to the right
Press and hold [AUD] key for 3 second or longer
“APPROVED” is displayed.
Reset, Momentary power down, ACC OFF, Power OFF, panel removed
Cancel the Test mode.
Note: The security code in this model cannot be all-cleared.