40
10 - ELECTRICAL INSTALLATION
The appliance must be connected to the electrical network verifying that the voltage
corresponds to the value indicated on the specifications plate and that the cables section
of the electrical wiring can bear the load which is indicated on the rating plate .
We recommend that the appliance is connected by a suitably qualified person who will
comply with the current IEE and local regulations .
It is recomended that the appliance is connected via a dedicated cooker circuit using a
double pole cooker switch with a rating equal or greater than the total loading of the cooker,
with a minimum opening between the contacts of 3 mm .
Alternative connection methods may be available as long as they conform to current IEE
wiring regulations .
The power supply cable must not touch the hot parts and must be positioned so that it does
not exceed 75°C at any point .
Once the cooker has been installed, the switch must always be easily accessible within 2
metres .
IMPORTANT: This appliance must be connected to a suitable double pole control
unit within 2 metres of the cooker.
No diversity can be applied to this control unit.
The control unit must be capable of breaking the full load current of the appliance.
IMPORTANT: The appliance must be installed in accordance with the manufacturer’s
instructions. Incorrect installation, for which the manufacturer accepts no
responsibility, may cause damage to persons, animals and property.
The connection of the appliance to earth is mandatory. The manufacturer declines
all responsibility for any inconvenience resulting from the inobservance of this
condition.
Before carrying out any work on the electrical parts of the appliance, the appliance
must be disconnected and locked off from the mains.