ELECTRICAL FEEDER CABLE CONNECTION
WARNING: The power supply cable must be connected only by an authorised service
agent in order to avoid a hazard.
If the power supply cable is damaged, it must be replaced only by an authorised
service agent in order to avoid a hazard.
To connect the supply cable:
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks “
A
” (fig. 11.1).
•
Unscrew the screw “
D
” and open completely the cable clamp “
E
” (fig. 11.2).
•
Connect the phase, neutral and earth wires to terminal board “
G
” according to the
diagram in fig. 11.3.
•
Strain the feeder cable and block it with cable clamp “
E
” (by screwing screw “
D
”) .
•
Close the terminal block cover (check the two hooks “
A
” are correctly hooked) .
NOTE: The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
POWER SUPPLY
230 V 50 Hz 4290 W
FEEDER CABLE SPECIFICATIONS
Type “H05RR-F” or “H05VV-F”
3 x 2,5 mm
2
A
Fig . 11 .1
Fig . 11 .2
Fig . 11 .3
230 V 50 Hz
230 V 50 Hz