
12
Top
Way
Technology
Top
Way
Technology
17.Visitors call remind(more than 1 indoor units)
17.Visitors call remind(more than 1 indoor units)
calls.
b. When the indoor unit is talking with outdoor unit, an
-
other outdoor unit calls in, the indoor unit in commu
-
a. When the indoor unit under stand-by, monitoring, call
-
ing, talking and without no-bother status, the indoor
unit and outdoor unit will ring while the outdoor unit
nication will sound “Di Di Di” discontinuously to remind
18. Alarm for room number confliction(more than 2 indoor units)
18. Alarm for room number confliction(more than 2 indoor units)
that there is another visitor call. At this time the indoor
When the room number of indoor unit is the same as
confliction.
19. Alarm for communication confliction(more than 2 indoor units)
19. Alarm for communication confliction(more than 2 indoor units)
and outdoor ones will not ring.
that of the others, the unit will sound discontinuous
“Di”, and then you need to change this number to avoid
When the indoor unit sounds “Di” every three seconds,
it shows the connection between the indoor and out
-
door unit has communication confliction. Please in
-
spect the circuitry or check the indoor monitor if in off
(Pic. Q) to connect with the outdoor, it quit the alarm
automatically.
Special
Functions
Special
Functions
If
the
system
is
working
properly, don't
set
the
room
no
.
Improper
setup
will
make
the
f
the
system
is
working
properly, don t
set
the
room
no
.
Improper
setup
will
make
the
system
in
trouble
.
system
in
trouble
.
When
all
indoor
units
and
outdoor
camera
are
install
-
ed, the
system
doesn't
work
properly
please
reinitia
-
lize
all
indoor
units
and
setup
the
room
numubers
.
Turn
off
the
unit, press
“Intercom”
button
at
the
same
time
press
“on
/
off”
(Pic. R)
to
turn
on
the
unit
.
The
sys
-
tem
will
sound
“Di”, and
release
“Intercom”
button
.
Now
the
“Talk”
LED
flashes
three
times
quickly
then
back
to
standby
.
The
initialization
finish, room
No
.
is
0
.
2
.
Indoor
unit
room
number
setup
-
automatically(more
than
2
indoor
unit)
2
.
Indoor
unit
room
number
setup
-
automatically more
than
2
indoor
unit
a
.
When
there
are
2
indoor
units
,
after
initialzation
of
all
indoor
units(see
point
1)
, press
“call”
from
outdoor
ca
-
mera
and
the
indoor
units
will
ring
.
The
unit's
room
b
.
When
there
are
more
than
2
indoor
units, after
initia
main
indoor
unit
and
no
.
2
indoor
unit
and
turn
them
on, press
“call”
from
outdoor
camera
and
the
indoor
lization
of
all
indoor
units(see
point
1), connect
the
units
will
ring
.
And
then
connect
no
.
3
indoor
unit
and
call
from
outdoor
unit
.
When
the
indoor
units
ring
,
the
no
.
3
indoor
unit
is
set
.
No
.
4
,
No
.
5
,
etc
.
3
.
Indoor
unit
room
number
setup
-
manual(more
than
2
indoor
unit
)
3
.
Indoor unit room number setup
-
manual more than 2 indoor unit
)
will
allocate the room number automatically. If you
want
to change the room number (Except the indoor
one which is connected to the outdoor unit
), it can
When there are more than 2 indoor units, the system
a. Please make the unit under power off status
.
be changed following bellowing steps:
b. After the first step, press and hold
“intercom”
button
(Pic. S)
at the same time press
“on
/
off”
button(Pic.
S
1),
when the
unit sounds
“Di”, release
“intercom”
button
and
“on
/
off”
button.Then press
“Open”
button
(Pic.S3)
three times
within 4 seconds. At this
time
working
LED will glitter three times and the
unit sound
which
stands
for the room number.
is
successfully completed.
ful
change and then turn on again.
“Talk” button(Pic.S2), the unit will sound
“Di”
and
c. Following the second step, each time you press
please check
the flash times of the working LED
d. After room number setting, press
“on
/
off”
button(Pic.
S2)
for
2s,
the
unit
will
sound
“Di”, and
the
working
LED glitter three
times and the room number
setting
e. After the room number setting, if the number is the
same as the others in this system, the unit will alarm
and sound
“Di”
discontinuously. You can reset the
room number or
change the conflicted one. Cut off
the power supply of the
alarming unit after success
-
Remark
During step b of point 3, if you fail to press
“
O
pen
”
button three times
The operation failed, you have to
restart from step a.
within 4 seconds, the working LED will return to glitter under standby.
Pic.S
Pic.S1
Pic.R
Pic.O
Pic.P
Pic.Q
Pic.S4
Pic.S3
Pic.S2
“Di”
and the no
bother LED will light up.
numbers
are
set
automatically
and
ready
to
work
.
13
status. Press “monitor” button(Pic. P) or “talk” button
1
.
Initialization
of
indoor
unit's
number
1
.
Initialization
of
indoor
unit s
number