background image

6

 

FACTORY DEFAULTS 

 
If  you  wish  to  reset  your

  GPMX-16

  to  factory  defaults,  you  can  do  so  by  turning  the  power  on  whilst 

holding  down  all  three  push  buttons  (mode,  dec  &  inc).  This  will  return  the 

GPMX-16

  to  it’s  default 

settings.  
‘Fd’ (factory defaults) will momentarily be displayed when this has been done.

 

 
 

DISPLAYING THE FIRMWARE VERSION NUMBER 

 

Power  the  unit  on  while  holding  the  ‘INC’  button  pressed.  While  the 

INC

  button  is  held,  the  firmware 

revision  number  [1xxx]  will  be  displayed  in  pairs  –  two  dashes  then  digits  1  &  2  then  digits  3  &  4 
repeated. Releasing the INC button will revert to the normal operational mode. 

 
 
 
 
 
 

SPECIFICATIONS 

 

Power Input 

 

 

9V DC – switch mode mains adaptor supplied  

 
Power consumption 

 

200mA max, 2.1mm plug (centre positive)  

 
MIDI 

 

 

 

In, Out1 & Out2 (out1 & out2 give the same data out) 

 
Inputs   

 

 

16 GPI – 8 on each of 2 x 9 pin D connectors – pin 9 common ground 

 
Outputs  

 

 

16 GPO – 8 on each of 2 x 9 pin D connectors – pin 9 common 

 
Display   

 

 

3 x 7 segment display 

 
Weight   

 

 

1Kg including PSU 

 
Dimensions 

 

 

190 x 110 x 45 mm 

 
Non-volatile memory 

 

EEPROM  (no back-up battery required)

 

 
 

WARRANTY 

 

The 

GPMX-16

  comes  with  a  12  month  (from  purchase  date)  back  to  base  warranty,  (i.e.  customer 

must arrange and pay for carriage to and from Kenton Electronics). 

 
 
 

 

 

Brookfarm House, 1 Station Road, South Wimbledon, London, SW19 2LP, UK 

Tel: +44 (0)20 8544 9200          Fax: +44 (0)20 8544 9300 

[email protected]             www.kenton.co.uk

 

firmware rev# 1001              e. & o. e. 

 30

th 

April 2014

 

Reviews: