To ensure that the purifier operates at its
carbon when the filter change alarm is audible
optimum level, a routine maintenance must be
OR after every 12 months. It is recommended to
performed. The frequency of the maintenance will
change the FRT when the filters are replaced
greatly depend upon the raw water quality and
Replace the RO membrane once in a year
consumption of treated water.
Replace the UV Lamp once in a Year
Storage tank must be drained once in 2 weeks.
If you are not going to use the purifier for a long
To do so, switch off the power supply, open the
time ( in case you are on a holiday, tour or out of
drain plug at the bottom of the tank & allow the
home), make sure that you disconnect the power
water to drain. Then screw back the plug and
supply, turn off the raw water supply and drain
switch on the power supply
the storage tank
Replace sediment, activated carbon & post
n
n
n
n
n
Maintenance
Replacement of spare parts are as under:-
-20008
SP Inline Sediment Filter 10"
-20009
SP Inline Carbon Filter 8"
-20001
SP RO Membrane Welded 10" Housing
-20015
SP Post Carbon Filter (Blue)
-20003
SP Hollow Fibre Membrane (RO)
-20020
SP FRT 300
7
n
n
n
n
n
n
Switch on the power supply
remove any dust particles present in the pipes
and storage tank
Wait till the storage tank fully fills up**
Close the drain plug & SS ball valve at bottom of
Switch off the power supply
storage tank and switch on the power supply
Drain the storage tank by opening the drain
The purifier is ready to use
plug & opening the SS ball valve by lever
present at the bottom of the storage tank so as to
Starting Up the Purifier
TM
of the valve anticlockwise; it will result in more mineral
A unique feature in
Supreme
Mineral RO
content in treated water. To reduce the TDS level, user
water purifier is the TDS control valve, which is not
can turn the screw valve clockwise; it will result in less
available in any other domestic water purifier till date.
mineral content in treated water. We recommend the
This feature allows the user to control the content of
TDS of the purifier to be kept at lowest but not
natural minerals (TDS) in purified water .
below 50 mg/l.
To increase the TDS level the user can turn the screw
KENT
TDS Adjustment*
Although the rejected water has high concentration
It has high concentration of salts and minerals which
of salts. This wasted water usually goes down the
accelerate plant growth. Rejected water can also be
drain but if required, can be used for gardening
used for cleaning purposes, i.e. utensils cleaning,
purposes.
mopping, etc.
Recommended Uses of Rejected Water
* Tested & Certified by TUV-SUD South Asia (P) Ltd.
** Tested or Certified flushing time -24hrs.
Open the SS ball valve mounted at the bottom
NOTE:- Do not obstacle the over flow pipe of
side of the rejected water tank (Handle parallel to
rejected water mounted at top left side of water
the ball valve) to start the flow of water whenever
Storage Tank
you require.
How to Use Stored Rejected Water
The reverse osmosis system contains a replaceable treatment component critical for the effective reduction
of total dissolved solids and that product water shall be tested periodically to verify that the system is
performing properly.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
TM
Performance Data Sheet-KENT Superme Mineral RO Water Purifier
Substance
Influent challenge
Maximum permissible
Minimum %
concentration mg/L
product water
reduction
concentration mg/L
Total Dissolved Solids
750 ± 40 mg/L
187
93.6%
Technical Specifications
Model Name
* Treatment capacity tested for tap water having TDS level of 750 ppm at room temperature
KENT Supreme
TM
Mineral RO
Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw water
and water consumption. They are not covered under the warranty. However, if a filter chokes within six months and a
membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters and system
inspection is available on call. The treatment capacity of RO membrane will reduce with time due to clogging of
pores of membranes.
“This reverse osmosis system contains a replaceable component critical to the efficiency of
Replacement of the reverse osmosis component should be with one of identical specifications as defined by the
manufacturer, to ensure the same efficiency and contaminant reduction performance.”
the system.
Arsenic (+5)
0.30±10%
0.010
98.7
Barium
10.0±10%
2.0
97.7
Fluoride
8.0±10%
1.5
96.3
Lead
0.15±10%
0.010
99.3
Nitrate / Nitrite
30±10%
10
73.5
8
Model No.
Applications
Purification Production Rate
Body Material
Mounting
Dimensions(mm)
Inlet Water Pressure/Temp (Min)
Inlet Water Pressure/Temp (Max)
Filter Cartridge
Auto-Flushing System
UV Lamp Wattage
Life of
Weight
Storage Capacity
Maximum Duty Cycle
Membrane Type
Booster Pump Voltage
Total Power Consumption
Input Power Supply
UV Lamp
11006
Upto 15 L/hr or 0.25 L/min*
ABS Food Grade Plastic
Wall Mounted
L 430 W 270 H 630
2
0.3 kg / cm or 4.267psi / 10ºC
2
3 kg / cm or 42.67psi / 35ºC
Sediment, Carbon Block Filter, UF and Post Carbon
Yes
11 W
1 Year
10.900 kg
9+9 L
75 L/day
Thin Film Composite RO
24 V DC
Single Phase 10
Suitable for purification of Brackish / Tap / Municipal Corporation Water
60 Watt
0 - 250 V AC, 50-60Hz, 800mA