Installation Instructions
To ensure purer water throughout the service cycle, KENT Pristine UV is equipped with an in-
built UV Fail Alarm which gets activated in the event of UV lamp failure. In case the UV lamp
malfunctions, the purification process automatically stops and the purifier starts emitting a
short beep at an interval of every 2 seconds.
UV Fail Alarm
Under such circumstances, please switch off the purifier and call the service technician for
help. The purifier will stop purification in such a situation.
KENT Pristine UV
has an in-built feature that sounds an alarm to indicate the replacement
time of filters. This alarm is audible after 700 hrs of filter use. The Filter Change Alarm works
as follows:
Gives 4 short beeps every two seconds, lasting upto 30 seconds. The alarm gets activated after
every 2 hours of use.
Filter Change Alarm
Under such circumstances, the purifier will not function unless the filters are changed.
Slot holes
Computer Controlled Operation
6
5
n
Wall/plane surface for mounting screws and holding the machine. Avoid installation
on wooden and metallic stands
Recommended Site Preparations:
n
For optimum inlet pressure, the source water tank should be at least 10ft above the
purifier installed
KENT Pristine UV
is a convenient and easy-to-install wall mounting model.
n
Raw water supply with ½ inch nipple not more than 3 m away
n
Installation space as per the dimensions of the purifier
n
The system and installation must comply with applicable state and local laws &
regulations
n
Single Phase 140-250 V AC, 50-60 Hz. supply not more than 3 m away from the point
of installation
n
Install the purifier near a sink for easy availability of inlet water lines
Installation Procedure:
1.
Screw in two 10x50 self taping screws,
apart horizontally.
5.7 inches (100 mm)
2.
Wall-mount the purifier with the help of the slot holes given on the back.
6.
Turn on the lever given on the SS ball valve to initiate water flow to the purifier.
3.
Fasten the SS ball valve to ¼ inch port of 3-way connector.
4.
Attach the threaded end of the 3-way connector to the raw water supply
and plug off the other end or connect to a tap.
5.
Now connect one end of the pipe to the SS ball valve and other end to
the elbow fitting connector labeled as WATER IN, on the left side of purifier.
Purification Delay:
To ensure that the water lying idle in the internal pipes and the UV chamber
is thoroughly disinfected before being passed onto the storage tank, the system provides
approximately 5 seconds of Purification Delay when the purifier is switched on. During this
period, all electrical devices except the UV lamp are switched off and the UV lamp kills the micro
organisms present in the water inside the UV chamber. After this delay, all other electrical
devices such as solenoid valve etc., get activated and the normal purification process starts.
To ensure the delivery of purer and healthier water, a micro processor is installed in the purifier
to performs the following functions:-
UV Stabilisation Delay:
To ensure that the UV lamp is pre-heated and is working at its optimum
before it starts disinfecting water, the controller provides a two second delay to the UV lamp
when a purifier is switched on. During this period, only the UV lamp is on and all other electrical
devices of the purifier are switched off and no water flows through.
Audible Alarm:
The microprocessor also controls the activation of the UV Fail Alarm and
Filter Change Alarm.
Please call the service technician once the Filter Change Alarm is activated and get the filters
replaced. In case the filters are not replaced within the next 60 hours of operation, the purifier stops
functioning to avoid the delivery of impure water and beeps continuously.