9. TECHNICAL DATA
Model
Gas Input kWh
Consumption g/hr
High
Med
Low
High
Med
Low
KCH205-002
4.2
2.6
1.5
306
190
109
Appliance Details
• With Oxygen Depletion Safety system and Anti-tilt Safety device
• Gas consumption: 306g/h
• Gas hose: Certified gas hose according to applicable EN-standard (recommend 50mm)
• Gas regulator: Certified according to EN12864 (flow rate max. 1.5kg/h)
10. TROUBLESHOOTING
Trouble
Probable Cause
Remedy
Piezo fails to light pilot
Note: when the heater is newly con-
nected it may take 2-3 attempts to
ignite the heater
1. Cylinder gas valve is closed
2. Insufficient LP gas
3. Insufficient spark to light the pilot
1. Open Cylinder gas valve
2. Refill cylinder
3. Check the spark gap between
the electrode and pilot (should be
4-5mm). Adjust if necessary
Pilot lights but will not stay lit
1. The thermoelectric flame failure
device has not engaged
1. Hold down the knob firmly for 10-
20 seconds after the pilot ignites
Pilot is large and a yellow/orange
colour
1. The heater requires a service
1. Contact your local Service Agent
Burners are not lighting properly
1. Insufficient LP Gas
2. Regulators excess flow device has
engaged
3. The heater requires a service
1. Refill cylinder
2. Turn the cylinder off for 5 minutes
Re-light the heater leaving on low
for 30 seconds before turning to
high
3. Contact your local Service Agent