background image

4

•  This appliance is designed to be used with a 9 kg LPG 

cylinder fitted with a horizontal valve outlet.

•  Do not use the appliance unless the chrome wire safety 

guard is in place.

•  Do not move the appliance when lit and operating. Be 

aware that even after use the appliance remains hot for 

several minutes.

•  The guard on this appliance is to prevent risk of fire or 

injury from burns and no part of it should be permanently 

removed. IT DOES NOT GIVE FULL PROTECTION FOR 

YOUNG CHILDREN OR THE INFIRM.

•  Avoid twisting the flexible tubing or the hose.
•  Do not use the appliance if it is leaking gas (see notes on 

how to check for a gas leak).

•  Keep children away from the appliance.
•  Keep the appliance away from flammable materials e.g. 

Clothes, curtains, upholstery, etc.

•  Always change the gas cylinder outdoors and away from 

any sources of ignition.

•  In the event of a burn back (where the flame burns back to 

the jet) immediately turn off the gas supply at the cylinder 

control valve. After ensuring that the flame is extinguished, 

re-light the appliance as described below. Should the 

appliance again burn back, close the valve and return 

the appliance to the your local LPG Service Agent for 

examination.

•  If there is an apparent gas leak on the appliance e.g. smell 

of gas, close the valve on the cylinder. Take the complete 

assembly outside into a flame free environment and test for 

the suspected leak as described below.

• Do not check for gas leaks with a flame as this 

is extremely dangerous!

•  To check for a gas leak, light the appliance and use a 

brush dipped in a soapy water solution (e.g. water with 

dish washing liquid added). Apply the brush to the suspect 

areas such as the cylinder valve spindle or where the 

regulator screws into the cylinder. Also check the joins 

between the hose and regulator and between the hose 

and appliance. If there is a leak then bubbles will form. 

Should this happen, turn off the gas supply at the cylinder 

valve.  
Inspect the condition of the seal fitted on the regulator and 

ensure that it is in good condition. Refit the appliance to 

the cylinder and re-test using the soapy water solution. 
If the leak persists then take the appliance and the cylinder 

to your local LPG Service Agent for inspection and / or 

repair.

•  Do not use in high rise flats, bedrooms, bathrooms, 

basements, toilets, caravans or mobile homes.

•  After use turn off the appliance at the gas cylinder valve.

2. SAFETY INFORMATION

IMPORTANT:

Read these instructions carefully before fitting the 

appliance to the gas cylinder. These instructions should 

be retained for future reference as they contain important 

safety information. 
Never use this appliance in areas where there is 

insufficient ventilation as this may cause oxygen depletion 

which could endanger the life of the occupants of the 

area. 
Never modify this appliance in any way as this will void 

your warranty and more importantly, may make it unsafe.

When operating this heater always ventilate 

the room by leaving a window which is at least 

60cm (600mm) wide open to outdoors by at 

least 2cm (20mm) while the heater is in use.
Do not use in a small room less than 86.4m³ (to 

ensure adequate ventilation/air changes). This 

is approximately 6m L x 6m W x 2.4m H. 
Do not use in high rise flats, bedrooms, 

bathrooms, basements, toilets, caravans or 

mobile homes.

•  This appliance requires assembly by a competent person.
•  This heater is operated by two controls:

-  The hand wheel on the LPG cylinder valve turns the 

gas supply ON/OFF.

-  The control knob which controls the gas flow for 

ignition and during operation.

IMPORTANT:

For safe operation of this heater, you must obey the 

following:
DO NOT   walk in front of the heater when lit.
DO NOT   move heater from room to room when lit.
DO NOT   place clothes or other objects on the heater.
DO NOT   position the heater within 1 metre of people,  

   

drapes, furniture and other objects.

DO NOT   use in high rise flats, bedrooms, bathrooms,   

   

basements, toilets, caravans, mobile homes or  

   

rooms under 86.4m³ floor area.

ALWAYS   face the heater towards the centre of the room.

Summary of Contents for KCH205-002

Page 1: ...d directly in front of the heater when attempting to light the heater Take care that your clothing is not in close contact with the safety guard or in front of the heater ASTRO PORTABLE LPG CABINET HEATER Model No KCH205 002 STEP BY STEP LIGHTING INSTRUCTIONS Important Retain these instructions for future use 4105 11 14 IMPORTANT PLEASE READ CAREFULLY BEFORE USE These instructions should be read i...

Page 2: ...point the outer tiles will be off and the centre tile and pilot will still be running 3 Reach into the back of the heater and turn the cylinder off by turning the valve hand wheel fully clockwise 4 Observe the centre tile and pilot to ensure they fully extinguish 5 Allow the heater to cool for approximately 30 minutes before moving or placing in storage WARNING Health warning Do not use if you suf...

Page 3: ...ge black knob clockwise while engaging the threads on the valve Fig 2 It is necessary to tighten the knob completely as the built in safety system will only allow gas to flow if a safe connection has been made It will take approximately 3 4 turns to firmly connect the regulator to the cylinder D Turn gas cylinder valve ON anti clockwise as shown in Fig 3 E Check for leaks on all connections using ...

Page 4: ...ply at the cylinder valve Inspect the condition of the seal fitted on the regulator and ensure that it is in good condition Refit the appliance to the cylinder and re test using the soapy water solution If the leak persists then take the appliance and the cylinder to your local LPG Service Agent for inspection and or repair Do not use in high rise flats bedrooms bathrooms basements toilets caravan...

Page 5: ...er that the hose is not trapped or kinked in any way Fit the heater rear panel to the heater by engaging the clips IMPORTANT Use only in a well ventilated room You require at least 105cm ventilation 6 CYLINDER SIZES The model KCH205 002 is designed for 9 0kg LPG Cylinders 7 LEAK WARNING Should you suspect that the heater is leaking turn OFF the cylinder valve and contact your local Gas Fitter or L...

Page 6: ...2 Insufficient LP gas 3 Insufficient spark to light the pilot 1 Open Cylinder gas valve 2 Refill cylinder 3 Check the spark gap between the electrode and pilot should be 4 5mm Adjust if necessary Pilot lights but will not stay lit 1 The thermoelectric flame failure device has not engaged 1 Hold down the knob firmly for 10 20 seconds after the pilot ignites Pilot is large and a yellow orange colour...

Page 7: ...ion befitting the age of the appliance 3 Exclusions This warranty does not cover a misuse of or failure to properly maintain the appliance b faulty installation c use of incorrect gas type or poor quality gas d if this product is required for business purposes the Consumer Guarantees Act 1993 shall not apply 4 Where this product contains information from an overseas country nothing in that informa...